You can also display the difference to the target weight in figures with + or - sign in the top left
corner of the secondary display. Enable the secondary display with the F3 Secondary Display key in
level 3 of the settings functions.
By saving the component to the totaling memory with the Plus key, the display of control special
characters is interrupted, and the Recipe display view is shown until the scale is again relieved. The
control special characters are then reenabled.
Block totaling of items outside of the tolerance
Totaling items outside of a specified tolerance range can be prevented. If the weight is outside of
the tolerance, the error message Error 27 "Outside of Tolerance" is displayed after pressing the F6
Plus key. For this purpose, Program Settings / Recipes / Totaling Outside of Tolerance must be
switched to "Within" in setup mode.
Displaying target value and tolerance
Press the key followed by the F2 Comp Contr. key.
Or: Press the Comp Contr. key in the Recipe Function level 1 .
Next component with changed target weight/tolerance
Press the F1 Comp. Contr. key and use the number keypad to enter the new target values.
Switching point for control
The terminal must have an I/O card installed if you wish to forward the control values with the
interface, e.g. to a control light or to a control. The I/O card must be enabled in setup mode under
Setup Mode / Communication / IO Control. The following default can be enabled under Program
Settings / Recipes / IO Default With Execution.
Switching point
Signal
S1
Weight value above toler.
S2
disabled
S3
Weight value within toler.
S4
Weight value below toler.
S5
Empty message
S6
Weight value above toler.
The individual inputs and outputs can be customized.