91
Scope Multimeter
Getting Started
Low Amp Current Probe (optional)
The optional Low Amp Current Probe provides accurate and reliable non-intrusive testing of
ignition coils, fuel injectors, fuel pumps, relays, electric motors, and parasitic draw. The optional
Low Amp Current Probe measures current from 10 mA to 60 Amps.
Figure 8-10
Low Amp Current Probe
8.1.3
Menu Icon Options, Scope Multimeter
The Menu icon on the Toolbar at the base of the screen opens a menu with the following options:
•
—opens the
Important Safety Instructions
document.
•
—allows you to print or save the data or meter setup being viewed.
•
—allows you to adjust certain tool settings once a test has been selected.
•
—allows you to view supporting documentation.
File
Use to print or save a copy of the data currently being viewed. Selecting opens a submenu:
•
Save Multimeter
—opens an additional submenu with these options:
–
Save Configuration
—saves the current screen setup as a preset for quick access.
–
Save Single Frame
—saves a recording of the current screen.
–
Save All Frames
—saves a recording of the current screen plus all the data in the buffer.
•
—opens a standard Windows Print dialog box for printing the current screen. A message
will display asking if you wish to print only the scope or the entire screen display. Answering
No will print the entire displayed screen.
Setup
This option allows you to adjust tool settings to your personal preferences. Selecting opens a
menu of the following:
•
—opens the Unit Setup dialog box to adjust trace and display settings
•
—opens the Snapshot dialog box for selecting how triggered data is saved.
•
—opens the Ignition dialog box for setting up to display secondary ignition patterns.
Содержание VERUS
Страница 1: ...User Manual EAZ0061B58A Rev E ...