83
Accessories
10-417 CHEMICAL CLEAN-LOAD
®
OPERATING INSTRUCTIONS
STARTUP
1. All Clean-load valves must be closed prior to starting: inlet ball valve, knife valve and hopper rinse ball valve.
2. Open lid to check for foreign objects which may hinder performance or contaminate the system.
3. Close and lock lid by turning cover clockwise.
4. Divert pump flow to Clean-load inlet line. A pressure of 30 PSI minimum and 150 PSI maximum must be used.
Highest pressures increase eduction rate and available wand suction.
5. Turn inlet ball valve on (yellow handle).
6. Open knife valve, located on the bottom of hopper, by pushing handle in (red handle).
7. Unlock and open lid slowly by turning cover counterclockwise.
LOADING LIQUID OR POWDERED CHEMICAL INTO HOPPER
8. Pour required amount of chemical into hopper. Avoid splashing liquids or powdered chemicals outside of hopper.
9. Rinse empty chemical containers if applicable. Place container opening over container rinse valve and press down.
This will activate the rinse valve and rinse container.
10. Rinse Clean-load hopper. Close and lock lid by turning cover clockwise. Release the safety locking band on the
hopper rinse ball valve and turn on for 20 seconds. Close ball valve and return locking band to locked position.
11. Open lid and inspect for chemical residue. Repeat step 10 as necessary.
12. Close knife valve by pulling red handle out towards you. Turn inlet (yellow handle) off.
LOADING LIQUID AND/OR POWDERED CHEMICAL WITH SUCTION LANCE
Note: Lance suction is dependent upon eductor pressure and flow. For best results, use highest pressure avail
-
able up to 150 PSI maximum.
8. Insert lance body with o-ring into eductor until the o-ring is sealed.
9. Use the free end of the lance to pierce bag or container to vacuum powdered or liquid chemical.
10. Rinse lance. Place lance end into a clean container of water to rinse lance assembly.
11. Remove lance body from eductor and drain any remaining fluid into hopper.
12. Close knife valve (red handle). Turn inlet valve (yellow handle) off.
SHUTDOWN
1. Ensure that:
• All valves are closed. Be sure to close knife valve first. (Close by pulling red handle out towards you.)
• Chemical residue has been cleaned.
• Hopper lid is closed and locked by turning cover clockwise.
2. Divert pump flow back to normal operation.
Содержание 100684
Страница 12: ...10 Diagrams WIRING DIAGRAM Use dielectric grease on all electrical connections ...
Страница 14: ...12 Diagrams HYDRAULIC DIAGRAM ...
Страница 16: ...14 Parts MAIN BODY DRAWING ...
Страница 18: ...16 Parts CONTROL PANEL DRAWING ...
Страница 20: ...18 Parts FRONT AXLE DRAWING ...
Страница 22: ...20 Parts SEAT CONSOLE AND ROPS DRAWING ...
Страница 24: ...22 Parts FUEL TANK DRAWING ...
Страница 26: ...24 Parts OIL TANK OIL FILTER OIL COOLER DRAWING ...
Страница 28: ...26 Parts FOOT PEDAL LINKAGE DRAWING ...
Страница 30: ...28 Parts PUMP DRAWING ...
Страница 32: ...30 Parts ENGINE AND SPRAY PUMP DRAWING ...
Страница 34: ...32 Parts PARK BRAKE DRAWING ...
Страница 36: ...34 Parts REAR AXLE DRAWING ...
Страница 38: ...36 Parts TANK DRAWING TURBO QUAD AGITATOR DRAWING ...
Страница 40: ...38 Parts 15 301 ORBITROL DRAWING ...
Страница 42: ...40 Parts 45 373 DDC20 PISTON PUMP DRAWING ...
Страница 53: ...51 Accessories NOTES ...
Страница 54: ...52 Accessories 17 835 BOOM DRAWING ...
Страница 65: ...63 Accessories NOTES ...
Страница 68: ...66 Accessories 16 906 ELECTRIC HOSE REEL DRAWING ...
Страница 70: ...68 Accessories 16 129 MANUAL HOSE REEL DRAWING ...
Страница 80: ...78 Accessories FOAMER NOZZLE MOUNT HOSE GUARD MOUNT DRAWING ...
Страница 82: ...80 Accessories 14 291 FOAMER REPLACEMENT PARTS ...
Страница 88: ...86 Accessories 15 620 CHEMICAL CLEAN LOAD DRAWING ...