Water Filling
After all the pipes are connected, open the discharge valve of the water heater and then the feed
valve. Fill the water heater with water and exhaust the air till a uniform water stream flows out of the
hot water outlet. This indicates that the water heater has been filled up. Close the hot water discharge
valve and check all connections for any leakage. If leakage occurs, empty the water tank, repair the
leaked connection and then refill the heater with water. Do not close the feeding valve during the filling
of water.
Installing the remote control
For convenience of operation, the control holder may be installed on a
wall near the water heater.
The remote controller must be installed at a dry area. Drill two holes on
the wall using an electric impact drill with 6mm bits. The holes must be
horizontal with 28mm of space between them. Fix the bracket on the
wall with expansion tubes and screws.
Remote control battery
The battery compartment is located at the back of the remote controller. Rotate the catch counter
clockwise with a coin to remove the battery cover. Load the battery into the controller, note that the ‘+’
end of the battery should face upwards. Replace the cover and rotate the catch clockwise to fasten it.