Installation
Caution
•
Please wait for 30 minutes before using the heater for the first time.
•
The heater should only be connected to a power source after a full installation which ensures
secure mounting, piping, wiring and filling of the tank with water.
•
To prevent injuries from lifting heavy equipment, the heat pump should be installed by at least 2
persons.
•
The heat pump must be lifted in an upright position. Do not tilt over a 45° angle. Disassembly and
assembly by end users are prohibited.
Mounting
This heat pump system should be installed at a location that is close to a power source, floor drain
and water utilization point. This heat pump system should not be installed in places filled with fumes,
strong electromagnetic waves, high fluctuations of power voltage, acid or alkaline vapor.
The air inlet of the heat pump system should be as far away from high temperature sources as
possible and should not be covered, as the outlet of the relief valve might discharge water during the
operation of the system. A floor drain must be provided near the heater.
Vertical installation of the water heater is strictly prohibited.
Mounting procedures and precautions
The installing surface must be capable of supporting at least four times the weight of the heat pump
system when filled with water. If the heat pump system is not installed on the bearing wall or is
mounted on hollow brick wall, corresponding protective measures must be provided.
Prior to confirming the positions of bolt holes, ensure that at least 300mm space on the right side of
the heat pump system is left unoccupied. This is to allow for easy maintenance.
If the heat pump system is embedded into a gusset plate, the plate on the right side should be
adjustable to allow for easy repair and maintenance. The distance between the gusset plate and front
of the heat pump system should be larger than 50mm, to ensure good ventilation during running of
the system under energy-saving mode. The heat pump may also be semi-concealed. Refer to Fig. 2
for details.
The heater should not be located outdoors or in an area subject to freezing environments. If freezing
occurs, the container and water pipe will break, causing scalds or leakage.