Caution
•
This heat pump must be installed with the fixing accessories provided. The heat pump must be
mounted only when the accessories are fixed firmly or the tank may fall and serious injuries
sustained.
•
The maximum wattage of the heat pump is 3200W, hence a single phase, dedicated power supply
is proposed. The core area of the electric supply wire should not be less than 2.5mm
²
.
Mounting guidelines
Drill two holes at least 105mm in depth using an electric impact drill with a Ø 10mm bit. The holes
must be level. Space between the two holes should be as shown below.
Model
L (mm)
HPW-60A
260
HPW-80A
380
A nylon expansion tube must pass through the hole of the mounting bracket first, and then inserted
into the drilled holes. It is necessary to use a special inner hexagon spanner to fasten the bolts into the
nylon expansion tubes, no other tools are permitted. During fastening of the screws, ensure that the
counter sunk head of the screw is not excessively tightened, which may damage the nylon expansion
tubes. Fix the hangers on the wall by using the inner hexagon spanner and expansion screws
Insert the square holes on the upper of supporting rack at the back of the water heater into the hanger
of the hanging plate, then move the water heater down to ensure the square holes against the root of
the hanger.
10
Fig. 1
Fig. 2
Содержание HPW-60A
Страница 1: ...Heat Pump HPW 60A HPW 80A User Guide...