30
331432-001
BLOWER EXHAUST DIRECTION
The blower assembly may be rotated 90 degree clockwise
or counterclockwise to allow horizontal venting in areas
having restricted space above the water heater. To rotate
the blower outlet, remove the four nuts (with 11/32” nut
driver) (see Figure 35), securing the
fl
ue collector to the
blower housing. Pull the blower assembly forward to free
it from the mounting studs. Rotate the blower housing
clockwise or counter-clockwise and align the four holes
and screws together. Reattach the blower housing to the
fl
ue collector.
11/32” nut
Note:
Coupling to vent system
not shown for clarity.
Figure 35
Read instruction manual before
installing, using or servicing
water heater.
•
Do not store or use gasoline or other flammable vapours
and liquids in the vicinity of this or any other appliance.
•
Avoid all ignition sources if you smell gas.
•
Do not expose water heater control to excessive gas
pressure.
•
Use only gas shown on rating plate.
•
Maintain required clearances to combustibles.
•
Keep ignition sources away from faucets after extended
period of non-use.
Fire or Explosion Hazard
WARNING