Instructions for the installer
25
3.
ELECTRICAL CONNECTION
Make sure that the voltage and capacity of the power line conform to the
data shown on the plate located under the casing. Do not remove this
plate for any reason.
The plug on the end of the supply cable and the wall socket must be the
same type and conform to the current electrical system regulations.
Check that the power line is adequately grounded.
On the power line, install an omnipolar cut-off device with contact cut-off
distance greater than or equal to 3 mm, located in an easily accessible
position near the unit.
Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must
not be less than 1.5 mm
2
(3 x 1.5 cable), keeping in mind that the end to
be connected to the hob must have the ground wire (yellow-green)
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has
a maximum temperature of 90°C. Any replacement needed should be
carried out by a specialised technician who should make the mains
connections according to the following diagram.
L = brown
N = blue
= yellow-green
The manufacturer will not be liable
for any damage to persons or
property caused by non-observance of the above instructions or deriving
from the tampering of even a single part of the hob.