Instructions for the installer
28
5.
ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.
The hob has been inspected for G25 (2L) at a pressure of 25 mbar. For
functioning with other types of gas the nozzles must be replaced and the
primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the
top as described in the following paragraph.
5.1
Removing the hob
1.
Remove all the knobs, the grids, the burner caps and the flame-caps;
2.
remove the screws and the nuts A that secure the burner supports;
3.
remove plates B;
4.
lift the hob from its seat;
5.
replace the burner nozzles in accordance with the reference gas
chart;
6.
regulate the primary air as described in paragraph “5.2 Regulation
for LPG”.