Instructions for the installer
30
5.3
Regulation for G25/25 mbar
The hob has been inspected for G25 (2L) at a pressure of 25 mbar. To
allow the unit to work with this type of gas, perform the same operations
described in paragraph “5.2 Regulation for LPG”, but choose the nozzles
and regulate the primary air for natural gas, as shown in the following
table and in paragraph "5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated heating
capacity
(kW)
G25 25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary (1)
1.05
76
380
Semi-rapid (2)
1.65
98
380
Rapid (3)
3.1
130
750
internal (4)
1.05
76
380
Double crown
internal (4)
3.9
150
1200
5.4
Regulation of primary air
Referred to distance “X” in mm.
BURNER
G25
25 mbar
G30/G31
30/30 mbar
Auxiliary
(1)
1.5
2.0
Semi-rapid
(2)
1.5
2.0
Rapid
(3)
2.0
9.0
internal (4)
3.0
6.0
Double crown
external (4)
3.0
10.0
(*) For burner reference numbers, see page 32.