Thermostat
•
Electric grill
AUXILIARY OVEN
•
Thermostat
•
Turn spit
•
Double speed cooling tangential
NOTE. NOT THE ALL REPORTED COMPONENTS ARE PRESENT ON EACH MODEL
3. Constructive principles
3.1. Cooling tangential system
The cooling system of the door ensures it has a continuous flow of air passing through it, eliminating residual heat and
external heat expel. This circulation is carried out by a mechanical fan (Tangential or Centrifugal) which creates the
flow of air passing through the slits in the door, as schematically indicated below.
this drawing shows the air flow created by a moto-tangential
fan .
The air is sucked from the surrounding room and spreads
through the door and expelled in the temperature ( the lower
temperature) which is expelled towards the bottom side.
On the other hand, the double oven cookers (ex: SUK62), the air flow is created thanks to a moto-fan (tangential)
whose air flow passes through slits positioned on the upper door and under the hob as shown in the following
drawing.
This drawing shows the air flow created by a moto-
tangential fan.
Hot air suction movement : the room cold air is sucked
and passes through the slits obtained on the front panel
and through the upper door , then the air is expelled from
the back slits.
The lower door has 4 glasses, not cooled.
9