Instructions for the installer
40
2.
INSTALLING THE APPLIANCE
The appliance must be installed by a
qualified technician
and
according to the regulations in force.
This appliance may be installed next to walls, one of which must be
higher than the appliance, at a minimum distance of 50 mm from the
side of the appliance, as shown in drawings A and B relative to the
installation classes. Any wall cupboards or ventilation hoods must be at
a distance of at least 750 mm above the work surface.
A
B
Built-in appliance
Free-standing
2.1
Electrical connection
Make sure the voltage and the cross-section of the power supply line
match the specifications indicated on the identification plate positioned
in the storage compartment.
Do not remove this plate for any reason.
The plug and wall-mounted socket must be of the same type (in
accordance with CEI regulations). Make sure that the supply line is
suitably earthed. Avoid the use of adapters and shunts.
Fit the power line with an omnipolar circuit-breaker with a contact
opening gap equal to or greater than
3 mm
, in an easily accessible
position close to the appliance.