No. TQ1230001-OM106-B
Ejector unit
Vacuum (V) port
Suction cup with adapter
(2) Mounting of the suction cup with adapter
(with O-ring)
6.2 Change to 1 cup (without flange)
*No mesh in the vacuum (V) port. If the mesh is necessary in the vacuum (V) port,
use the vacuum gripper
with cup mounting flange.
1. Disassemble the cup mounting flange
(1) Loosen the bolt (M6x10), then remove the cup mounting flange.
Be careful not to lose the O-ring.
(2) Remove the parallel pin.
2. Mounting of the suction cup with adapter
(1) Remove the suction cup with adapter from the cup mounting flange with cup removed in the process
1 above.
(2) Confirm the gasket seal in the adapter, then mount the suction cup with adapter removed in the process
(1) to the product.
Reassemble the parts by reversing the disassembling process with specified tightening torque.
Caution
T
ightening torque: 1N
・
m, (As reference, tighten by 45 degrees using a spanner after tightening by hand))
If tightened excessively, thread portion may be damaged and gasket may be deformed. This will cause air
leakage. Insufficient tightening may loosen the thread or cause air leakage.
Completion drawing
Parallel pin
Cup mounting flange
Suction
cup with
adapter
Hexagon socket head cap screw (M6x10)
Tightening torque 5.2±0.5N
・
m
(1) Disassemble the cup mounting flange