-54-
NO.ZK2-OM00501-B
■
Error Indication
This function is to display error location and content when a problem or an error occurs.
Error Name
Error Display
Error Type
Troubleshooting Method
Over current Error
The switch output load current is more
than 80 mA.
Turn the power off and remove the
cause of the over current.
Then turn the power on.
Zero-clear Error
During the zero clear operation,
pressure above ±3.5%F.S. has been
applied.
After 1 second, the mode will return to
measurement mode. The zero clear
range can vary ±1%F.S. with
individual product differences.
Perform zero clear operation again
after restoring the applied pressure to
an atmospheric pressure condition.
Pressurizing Error
Pressure has exceeded the upper limit
of the set pressure range.
Adjust the applied pressure to a level
within the set pressure range.
Pressure has exceeded the lower limit
of the set pressure range.
System Error
Displayed in the case of an internal
data error.
Turn the power off and turn it on again.
If resetting fails, an investigation by
SMC Corporation will be required.
If the error can not be reset after the above measures are taken, then please contact SMC.
Содержание ZK2-ZSV-A Series
Страница 22: ...21 NO ZK2 OM00501 B Reversed output out1 A...