HRX-OM-M090
Chapter 3 Transport and Setting Up
3.7
Wiring of external switch
HRS Series
3-24
3.
Plug the prepared connector in to the contact input/output connector that is on the back
of the thermo-chiller.
Fig. 3-18 Connecting the connector
3.7.3 Setting
items
Table 3-9 shows the setting items of the external switch. For details, refer to
5.19 Communication function.
Table 3-9 Setting list of the external switch
Display
Item
Initial value
(Default setting)
Example
∗
Reference
page
Category
Communication mode
LOC
LOC
Contact input signal 1
RUN
SW_A
Contact input signal 1 type
ALT
ALT
Contact input signal 1
delay
timer (time delay) of
reading
0 0
Contact input signal 1 OFF
detection timer
0 2
Contact input signal 2
OFF
OFF
Contact input signal 2 type
ALT
-
Contact input signal 2
delay
timer (time delay) of
reading
0 -
Conta
ct input
/output comm
unication
Contact input signal 2 OFF
detection timer
0 -
5.19
Communication
setting menu
∗
Example: Connect flow switch A to contact input signal 1 in local mode.