HRX-OM-M090
Chapter 3 Transport and Setting Up
3.2
Installation
HRS Series
3-4
3.2.1 Environment
The product must not be operated, installed, stored or transported in the
following conditions. Potential malfunction or damage to the product may
occur if these instructions are disregarded.
The product does not conform to any Clean room specifications. The pump
and ventilating fan inside the product generate particles.
The installer/end user is responsible for carrying out an acoustic noise risk
assessment on the equipment after installation and taking appropriate
measures as required.
z
Location that is outside.
z
Location that is exposed to water, water vapour, steam, salt water or oil.
z
Location that is exposed to dust or powder material.
z
Location that is exposed to corrosive gas, organic solvent, chemical
solution, or flammable gas (the product is not flame-proof)
z
Location where the ambient temperature is out of the following range:
In transportation and In storage 0 to 50°C
(with no water or circulating fluid in piping)
In operation 5 to 40°C (Option G [High temperature
type]: 5 to 45°C)
z
Location where the ambient humidity is out of the following range or where
condensation occurs:
In transportation and storage 15 to 85%
In operation 30 to 70%
z
Location that is exposed to direct sunlight or heat radiation.
z
Location that is near heat sources and poor in ventilation.
z
Location that is subjected to abrupt changes in temperature.
z
Location that is subjected to strong electromagnetic noise (intense electric
field, intense magnetic field, or surges).
z
Location that is subjected to static electricity, or conditions where static
electricity can discharge to the product.
z
Location that is subjected to strong high frequencies raditation
(microwaves).
z
Location that is subjected to potential lightning srtike.
z
Location at altitude of 3000m or higher (except during product storage and
transport).
∗
Because of lower air density, the heat radiation efficiencies of the devices
in the product will be lower in the location at altitude of 1000m or higher.
Therefore, the maximum ambient temperature to use and the cooling
capacity will lower according to the descriptions in the table below. Please
select the thermo chiller considering the descriptions.
1. Max. ambient temp.: Use the product in lower ambient temperature than
the described value at each altitude.
2. Cooling capacity coefficient: The product’s cooling capacity will lower to
one that multiplied by the described value at each altitude.
Содержание Series HRS012-A
Страница 8: ...HRX OM M090 Contents HRS Series...
Страница 144: ...HRX OM M090 Chapter 8 Control Inspection and Cleaning 8 4 Stop for a Long Time HRS Series 8 10...
Страница 145: ...HRX OM M090 Chapter 9 Documents HRS Series 9 1 Specifications List 9 1 Chapter 9 Documents 9 1 Specifications List...
Страница 162: ...HRX OM M090 Chapter 9 Documents 9 10 Daily Check Sheet HRS Series 9 18...
Страница 165: ......