-17-
No.PS
※※
-OMU0012-A
Outline of Settings
Power is supplied
The product code is displayed for approximately 3 sec. after supplying power.
After that, measurement mode is displayed.
: Within approximately 0.2 second after power-on, the switch starts.
[Initial Setting]
(Refer to page
Set the pressure range, display unit and switch output NPN/PNP specifications of the connected sensor.
[Measurement mode]
Detects the pressure after power is supplied, and indicates the display and switch operating status.
This is the basic mode; other modes should be selected for set-point changes and other function
settings.
Measurement mode screen
Sub display
In measurement mode, the display of the sub display can be temporarily changed by pressing the
or
buttons.
: One arbitrary display mode can be added to the sub display by setting the [F10] sub display setting.
If the sub display is switched during the arbitrary display setting, the display will be returned to the arbitrary display
30 seconds later. (The default setting does not include arbitrary display.)
Press the
button
once.
Press the
button
between
1 and 3 sec.
Press the
button
between
3 and 5 sec.
[3 step setting
mode]
Set either of set
value or hysteresis.
(Refer to page
[Simple setting
mode]
Select the set
value, hysteresis
and delay time.
(Refer to page
[Function
selection mode]
Change the
function settings.
(Refer to page
[Other Settings]
•Zero-clear function
•Key-lock function
(Refer to page
: The outputs will continue to operate during setting.
: If a button operation is not performed for 3 seconds during the setting, the display will flash.
(This is to prevent the setting from remaining incomplete if, for instance, an operator were to leave during setting.)
: 3 step setting mode, simple setting mode and function selection mode settings are reflected each other.