[F82] Input of line name
Function to display the specified character string on the sub display.
To display in the measurement mode, select 2 value display [dUAL] or character string display [LinE] using
the setting on [F10] Sub display setting.
<Operation>
Press the
or
button in function selection mode to display [F82].
Press the
button.
Move on to input of line name.
Input of line name
Press the
or
button to input the line
name displayed on the sub display (right).
Press the
button to make the next digit to the right flash. Input the
line name.
(The most significant digit flashes when the
button is pressed at the least significant digit.)
The order of displayed characters is A
b
• • •
Y
(Z)
0
1
• • •
9
symbol
space.
(Characters which can be displayed are different for 1 digit on the left and 3 digits on the right.)
Pressing the
and
button simultaneously adds/deletes the dot (decimal point).
The set line name flashes by pressing the
button for 1 second or longer.
(At this point, the setting of the line name is not complete.)
Press the
button to set.
Return to function selection mode.
[F82] Input of line name completed
•Characters which can be displayed for each digit are as follows.
(Pattern for 3 digits on the right)
Characters Q, X, Z, /, or
cannot be displayed.
(Pattern for 1 digit on the left)
Characters A to Z can be displayed (the same as the 3 digits on the right).