6.3 Parallel input / output signal
Item
Specifications
Connector
Manufacturer: J.S.T. Mfg. Co.,Ltd.Manufacturer: J.S.T. Mfg. Co.,Ltd.
Product number
:
PADP-14V-1-S
Cross sectional
area of the cable
AWG26
Length
(
L
)
The suffix of the part number (1,3,5) specifies the length.
LEC-CK4-1:
1.5m
LEC-CK4-3:
3m
LEC-CK4-5:
5m
Termi
nal
No.
Insulation
color
Dot
Mark
Dot
color
Func
tion
Contents
1 Light
brown
■
Black
COM
+
Connect the 24V side of the power supply (24VDC) for
input / output signal.
2 Light
brown
■
Red
COM
-
Connect the 0V side of the power supply (24VDC) for
input / output signal.
3 Yellow
■
Black OUT0
4 Yellow
■
Red
OUT1
5 Light
green
■
Black OUT2
6 Light
green
■
Red
OUT3
Operation completion output (Output with the
combination of OUT0 to 3)
OUT3
OUT2
OUT1 OUT0
OFF OFF ON ON
7 Gray
■
Black
BUSY
BUSY signal (Output during operation)
8 Gray
■
Red ALARM ALARM signal N.C.
(Turned off during alarm or when servo is turned off)
9 White
■
Black IN0
10 White
■
Red
IN1
11 Light
brown
■■
Black IN2
12 Light
brown
■■
Red
IN3
・
Operation command input
(Input with thecombination of IN0 to IN3)
・
Input return to origin position command
(Turn on IN0 to 3 simultaneously)
Ex. (Commands position number 5 to operate)
IN3 IN2 IN1 IN0
OFF
ON OFF ON
13 Yellow
■■
Black RESET
Interruption or alarm reset
During operation: The speed is reduced from the point
where signal is input until the
actuator stops. (Servo stays ON)
Alarm is being generated: Alarm reset
14 Yellow
■■
Red STOP STOP command (Sudden deceleration to turn off
servo)
* Parallel I/O signal is valid in auto mode. While the test function operates at manual mode, only the
output is valid.