![SMC Networks EX600-AX Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/smc-networks/ex600-ax/ex600-ax_operation-manual_1299349011.webp)
- 11 -
No.EX##-OML0007
Mounting and Installation
Installation method
Direct mounting
When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate
reinforcing brace (EX600-ZMB1) before mounting (Refer to the figure below.) using 2xM4 screws
(Tightening torque: 0.7 to 0.8 N•m)
Intermediate reinforcing brace
(EX600-ZMB1)
Fix and tighten the end plate at one end of the unit as shown in the figure below.
(Tightening torque: 0.7 to 0.8 N•m)
Fix the end plate at the valve side after referring to the manual of the corresponding manifold valve.
2 M4 screws
(tightening torque: 0.7 to 0.8 Nm)
End plate
Manifold valve
Intermediate reinforcing brace
2 M4 screws
117
0.
2
90
0
.2
23.5
47xn
5.5
8
26
8
47
47xm
(Tolerance: 0.2 mm)
2 x M4 screws
(Tightening torque: 0.7 ~ 0.8 N•m)
Intermediate reinforcing brace
2 x M4 screws
(Tolerance: ±0.2 mm)