Command Line Interface
4-102
4
6.
Specify a remote engine ID where the user resides (page 4-103).
7.
Then configure a remote user (page 4-109).
• The switch can send SNMP version 1, 2c, or 3 notifications to a host IP
address, depending on the SNMP version that the management station
supports. If the
snmp-server host
command does not specify the SNMP
version, the default is to send SNMP version 1 notifications.
• If you specify an SNMP Version 3 host, then the community string is
interpreted as an SNMP user name. If you use the V3 “auth” or “priv” options,
the user name must first be defined with the
snmp-server user
command.
Otherwise, the authentication password and/or privacy password will not
exist, and the switch will not authorize SNMP access for the host. However, if
you specify a V3 host with the “noauth” option, an SNMP user account will be
generated, and the switch will authorize SNMP access for the host.
Example
Related Commands
snmp-server enable traps (4-102)
snmp-server enable traps
This command enables this device to send Simple Network Management Protocol
traps or informs (i.e., SNMP notifications). Use the
no
form to disable SNMP
notifications.
Syntax
[
no
]
snmp-server enable traps
[
authentication
|
link-up-down
]
•
authentication
- Keyword to issue authentication failure notifications.
•
link-up-down
- Keyword to issue link-up or link-down notifications.
Default Setting
Issue authentication and link-up-down traps.
Command Mode
Global Configuration
Command Usage
• If you do not enter an
snmp-server enable traps
command, no notifications
controlled by this command are sent. In order to configure this device to send
SNMP notifications, you must enter at least one
snmp-server enable traps
command. If you enter the command with no keywords, both authentication
and link-up-down notifications are enabled. If you enter the command with a
keyword, only the notification type related to that keyword is enabled.
Console(config)#snmp-server host 10.1.19.23 inform retries 10 timeout 30
batman version 2c udp-port 162
Console(config)#
Содержание 8124PL2
Страница 1: ...MANAGEMENT GUIDE TigerSwitchTM 10 100 1000 24 Port Managed Switch with PoE SMC8124PL2 ...
Страница 2: ......
Страница 20: ...xvi Contents ...
Страница 27: ...xxiii Figures ...
Страница 35: ...Introduction 1 8 1 ...
Страница 45: ...Initial Configuration 2 10 2 ...
Страница 148: ...Port Configuration 3 103 Figure 3 61 Displaying Etherlike and RMON Statistics ...
Страница 473: ...Command Line Interface 4 240 4 ...
Страница 477: ...Software Specifications A 4 A ...
Страница 489: ...Index Index 4 menu list 3 3 panel display 3 3 ...
Страница 490: ......