HSC960 Genset Controller User Manual
HSC960 Genset Controller Version:1.0 2015-05-21 Page 18 of 37
No.
Function
Cable
Size
Remarks
13
2.5 mm
2
14
CHARGER(D+)
1.0 mm
2
Connected with charger starter‟s D+ (WL)
terminals. Being hang up If there is no this
terminal.
15
Gens AC Voltage (U)
1.0 mm
2
Connected to U-phase of generator (2A fuse is
recommended).
16
Gens AC Voltage (V)
1.0 mm
2
Connected to V-phase of generator (2A fuse is
recommended).
17
Gens AC Voltage (W)
1.0 mm
2
Connected to W-phase of generator (2A fuse is
recommended).
18
Gens AC Voltage (N2)
1.0 mm
2
Connected to N-phase of generator.
19
DC12V Negative
1.5 mm
2
Connected with Tps DC
engine for power supply.
Connected to Tps
20
DC12V Positive
1.5 mm
2
21
DC Gens Negative
1.5 mm
2
Connected with Tps DC
engine.
22
DC Gens Positive
1.5 mm
2
23
Position Positive
1.0 mm
2
Supply positive pole for
position sensor.
24
Position Signal1
1.0 mm
2
Connected to the signal
of forward direction (the
larger the aperture of Tps
is, the higher the signal
voltage is.)
25
Position Negative
1.0 mm
2
Supply negative pole for
position sensor.
26
Position Signal2
1.0 mm
2
Connected to the signal
of reverse direction (the
larger the aperture of Tps
is, the lower the signal
voltage is.)
27
MP1
0.5 mm
2
Connected with Speed sensor, shielding line is
recommended.
28
MP2 ((B-) has already
connected)
29
GOV
1.0 mm
2
Connected to external GOV speed regulation
signal.
30
Temp Input
1.0 mm
2
Connected to resistance
sensor
of
water
temperature or cylinder
temperature.
Details see Table 11
31
Pressure Input
1.0 mm
2
Connected to resistance
sensor.
32
Level input
1.0 mm
2
Connected to oil pressure
resistance sensor.