38
SMARTEK Vision | User Manual
– LED Strobe Controller Family | Doc. v2.2.1
Figure 26: ScLibClient
– Connect to Device
7.3. Ethernet Specific Discovery Options
When using an Ethernet connection, the user can choose between
Broadcast
and
search by
IP. Broadcast
is the default option and the fastest way to discover devices within the home
network.
Search by IP
is designed to find controllers that are connected to the outside of your home
network (via a router), where broadcast packages would not reach the device. Range of IP
search is 16 addresses and takes approximately 1 second per IP address. If your input exceeds
this range (as shown in Figure 22), 16 addresses will be searched starting with the address in
the left box.
Note:
Search for IP
is currently supported only by HPSC1 v2, HPSC2 and HPSC4 devices and
this will not find and IPSCx or HPSC1 Strobe controllers.
Figure 27: ScLibClient
– Search by IP
Depending on the type of connection that is used towards the strobe controller, the results of a
search might be different. Figure 28 shows how correct detected devices with a valid IP address
are listed.