APPENDIX B
MANAGING THE DISPLAY USING RS-232
68
IMPORTANT
Use only a standard RS-232 cable. Do not use a null modem cable. Null modem cables typically
have ends of the same type.
TIP
SMART also offers SMART Remote Management cloud-based device-management software,
which you can use to manage SMART Board interactive displays with iQ and devices running
Windows, Chrome™ OS, Android™, and iOS operating systems. For more information, see
Configuring the computer’s serial interface
settings
Configure the computer’s serial interface before sending commands to the display.
To configure the computer’s serial interface
1. Turn on the display.
2. Turn on the computer, and then start the serial communications program or terminal emulation
program.
3. Activate local echo.
4. Configure the serial interface settings using the following values, and then press ENTER.
Baud rate
19200
Data length
8
Parity bit
None
Stop bit
1
A command prompt (>) appears on the following line, and the display can now accept
commands from the computer.
NOTE
If no message appears or an error message appears, the serial interface isn’t configured
correctly. Repeat steps 3 and 4.