Unit Description
SMA
Technologie AG
Page 26
WB1100LV-11:FE2606
User Manual
Display Messages During Operation
The display shows the Windy Boy's most important operating data in a continuous
cycle. The following three screen images serve to clarify the display messages. Each
message is displayed for 5 seconds. Then the cycle begins again.
The energy generated today and the current
operating mode are displayed first.
Subsequently, the present feed-in power and the
output voltage are displayed.
This is then followed by the total energy produced so
far and the operational hours of the device.
Fault Displays
If an operational fault occurs, the display immediately
switches to "Disturbance" and the background
illumination is switched on.
The cause of the fault is displayed for 5 seconds in the second line of the display.
If a measured value is responsible for the fault
condition, then the value measured at the time of the
fault is displayed. If another measurement is possible,
the present value is displayed in the second line.
After another 5 seconds, normal operating data is
again displayed.
If the fault is still present, the fault display starts again from the beginning. An overview
of the status and error messages can be found in section 10.2 "Error Messages" (Page
64) of this document.
"Error ROM" indicates that the Windy Boy has
detected an error in the EEPROM firmware. Contact
SMA to have the error corrected.
The amount of energy shown under "E-today" does not necessarily reflect the
amount of energy produced over the last 24 hours. This is rather the energy
produced by the Windy Boy since the last deactivation / activation.
E-today 3.86kWh
Turbine Mode
Pac 903W
Vac 40V
E-total 724.4kWh
h-total 512h
Disturbance
Vac-Bfr
at: 261V
Turbine Mode
Error
ROM
Содержание Windy Boy WB 1100LV
Страница 2: ......
Страница 6: ...Explanation of Symbols Used SMA Technologie AG Page 6 WB1100LV 11 FE2606 User Manual...
Страница 10: ...Safety Instructions SMA Technologie AG Page 10 WB1100LV 11 FE2606 User Manual...
Страница 28: ...Unit Description SMA Technologie AG Page 28 WB1100LV 11 FE2606 User Manual...
Страница 30: ...Setting the Display Language SMA Technologie AG Page 30 WB1100LV 11 FE2606 User Manual...
Страница 40: ...Turbine Operation SMA Technologie AG Page 40 WB1100LV 11 FE2606 User Manual...
Страница 42: ...Maintenance and Care SMA Technologie AG Page 42 WB1100LV 11 FE2606 User Manual...
Страница 50: ...Extensions SMA Technologie AG Page 50 WB1100LV 11 FE2606 User Manual...
Страница 54: ...Technical Data SMA Technologie AG Page 54 WB1100LV 11 FE2606 User Manual...
Страница 72: ...General Information SMA Technologie AG Page 72 WB1100LV 11 FE2606 User Manual...
Страница 74: ...Stand Alone Systems SMA Technologie AG Page 74 WB1100LV 11 FE2606 User Manual...
Страница 77: ......