Ref : 26702 29 07/01/15
DETAILS ABOUT FAILURES TO OPERATE
The card indicates only the faults which it can
detect via the mains power, encoder and motor
links.
Err0
End of fault
Normal operation restored.
Err1
Memory fault
Operates in fail soft mode.
Reprogram all the parameters and do the travel learning again and
save the parameters.
Err2
Blank power card
Blocks the motor commands.
Check the shieldings, internal foreign body, link braid between
cards, etc.
Err3
High temperature
Wait for the temperature to decrease by 5°C. The motor can no
longer be commanded during this time interval.
Improve the ventilation of the motor and card, lower the voltages
U1, etc.
Err4
Motor overcurrent detected
Stops the motor for 0.5 seconds. If the fault occurs more than five
times in less than a minute, the message remains displayed and the
motor can no longer be commanded for 1 minute.
Check the motor, wirings (short-circuit), voltages U1.
Err5
Overload detected
Reduces the value of the voltage applied to the motor to limit the
overload.
Check the motor, reduce the voltages U1, ventilate better.
Err6
Counting or driving fault.
Operation goes into fail soft mode.
Check the encoder, motor, increase the voltages U1.
Err7
Mains overvoltage fault (higher than 270V)
Mains voltage too high or voltage generated due to a slowing down
of a heavy door with a Brushless motor.
Does not block the motor commands, but could destroy the
power supply.
Change the mains power supply to reduce the voltage or lower the
deceleration slopes.