Ref : 26702 24 07/01/15
The hold open order
forces the door to open at slow speed.
The hold close order
forces the door to close at slow speed
.
Adjustments :
To allow the adjustment of the door, when the
inspection
command is activated, the CMD commands from the
ARIANE
keyboard
remain active and all the manual commands may be deliberately activated
and performed.
PARAMETERIZABLE RELAYS OPERATION
Two relay outputs, RMF1 and RMF2, may be equally assigned to four
functions :
A)
Intermediate end stop :
The relay commands the placement of the end stop of an
intermediate open command.
This function allows improving the flow by using a large clear
opening goods lift in a
passenger
function by reducing the opening
travel.
B)
Electromagnetic suction disc :
The relay commands the activation of an electromagnetic suction
disc to keep the door closed. This function controls the de-activation
when the open order appears by applying a short timeout at the
departure of the door panels to allow a complete demagnetisation.
C)
Buzzer :
It is activated during a reset after a power failure, during
a nudging (slow forced closing) and during forced CMD keyboard
commands.
D)
Electro-cam :
The electro-cam command is managed according to
the door type :
o
For the door types
BATT
or
MOBI
, with operators in front
of the swinging doors, the card releases the electro-cam at
the end of the opening movement in accordance with the
standard NFP 82-212 article 4.2.14.a)
o
For the automatic door type
FI
unlocked by the electro-
cam, the card releases the electro-cam when the open order
appears by applying a short timeout at the departure of the
door panels to allow the time for the lock to be unlocked.
Warning : these commands correspond to the driving of
a dry contact. The ARIANE card does not provide power
for the driven devices.
Содержание ARIANE 3.1
Страница 26: ...Ref 26702 26 07 01 15 Pressing any key switches the display on ...