background image

Ref : 26702                                                         22                                                                07/01/15 
 

PART 7 : Details about the ARIANE 3.1 operations  

 

 

BASIC OPERATION 

 

Opening :

 The open order starts the open cycle if the close or nudging 

orders are not activated. 

The engaged cycle is terminated even if the open order is de-activated and 

ends the opening travel.  

At the beginning of the opening operation, if the landing door is not 

unlocked, the card closes and opens the door three times in an attempt to 

unhook the door. 

If the landing door refuses to be opened, the card ends the opening travel 

and waits for the close order. 

While opening an unglazed door, if an obstacle hampers the movement, 

the door tries to continue to open, but if it is blocked, it ends its opening 

travel and waits for the close order. 

While opening a glazed door, if an obstacle hampers the movement, the 

door stops, closes slightly and resumes its open cycle (Cycle to protect 

fingers by preventing finger jamming). 

 

Closing :

 The close order starts the close cycle even if the open order is 

activated (this allows overriding the open order and operating only with a 

close order). 

The engaged cycle is terminated even if the close order is de-activated 

(case of controllers operations which de-activate the order as soon as they 

are shunted even though the skate is still not closed).  

While closing, if the door encounters an obstacle, it triggers the shock 

output and goes into slow speed if it is in slave mode, or else the door is 

opened if it is in master mode. 

When the door closes after a shock, it slows down where the shock occurred 

to not hit the obstacle if it is still there. 

When the door and the skate have terminated the close cycle, the closing 

limit switch is actuated.  

 

Nudging :

 The nudging order is a close command at slow speed without 

obstacle detection. While closing, the buzzer output is activated. 

The nudging order has priority over the open order. 

 

Intermediate opening :

 This order operates like the open order by 

actuating the intermediate end stop output on which the door has just 

stopped while opening and gives the opening limit switch. 

 

Содержание ARIANE 3.1

Страница 1: ...AR OPERATOR CARD ARIANE 3 1 180W Asynchronous Brushless Motors COMMISSIONING MANUAL Parc d Activités Lyon Sud Ouest 4 route du Dôme F 69630 CHAPONOST Tel 0033 04 78 86 81 00 Fax 0033 04 78 86 81 08 Email slycma groupe ruget com ...

Страница 2: ... of the door A few particularities Driving the Asynchronous or Brushless motor The ARIANE 3 1 card allows driving both of these types of motors with a 230V voltage and a 180W maximum power rating Taking into account the Inspection mode Inspection signal input to be mandatorily wired to prohibit automatic door movements during technical services Managing glazed doors VITR and DURF parameters This o...

Страница 3: ...coder points _ _ display of the card Input Output state Parameter setting mode PARA Changing the parameters In the PARA mode you can access all the door configuration parameters and operating values Scroll the configuration parameters successively press Scroll the operating values successively press To read the value press To change the value press or To save the new value press To quit the mode s...

Страница 4: ...age 13 PART 4 Adjustment of the door operation Operating diagrams Page 14 Changing a parameter Page 14 Operating values Page 15 Value range table Page 16 PART 5 Saving the parameters Saving the parameters Page 17 Recording your own parameters Page 18 PART 6 Details about the command modes CMD The command modes CMD Page 19 Special case of a double opening travel Page 20 PART 7 Details about the ARI...

Страница 5: ...nt from 0 volts power the card via an insulating transformer example case of connection in TI state ASYNCHRONOUS MOTOR CONNECTION 4x minifit made in factory Make sure that the motor cable shielding is properly connected to the Ariane card package Make sure that the motor s ground is connected to the connector EMC requirement BRUSHLESS MOTOR CONNECTION 4x motor minifit and 6x hall effect sensors mi...

Страница 6: ...he safety chain to the 2 x 5 08 connector Check the factory wiring of the door contacts on the 4 x 5 08 connector is conformity with the electrical drawing regarding there is one or two contacts One in lateral opening 2 in central opening There is no interaction between the card s operation and the safety contacts CONTROLLER COMMANDS CONNECTION 6 x 5 08 connector All the orders must come from dry ...

Страница 7: ... connected in series with the cabin cell s NC signal input If necessary for the cell a 12V power supply is provided The use of this input is conditioned by the CELL and MODE parameters CONTROLLER SIGNALS CONNECTION 6 x 5 08 connector Connect the Limit switch and Shock signal returns to the controller These signals are dry contact relay outputs which require minimum switching currents of 10mA The d...

Страница 8: ...buzzer which will be activated during the learning reset nudging and fail soft operation An electromagnetic suction disc which will keep the door panels closed An electro cam which will unlock swinging doors or articulated sliding doors An electromagnetic intermediate open end stop External power supplies must be provided for the devices The maximum interrupting capacity of the relays is 6A for 25...

Страница 9: ...ete opening NO command input 33 Common 0V of the commands PART 2 Configuration according to the controller Scroll the menus by successively pressing and select PARA by pressing Scroll the parameters with To read the value press To change the value press To save the new value press SETTING OF THE MANDATORY PARAMETERS Display order of the parameters MSTF Hold under voltage closing OUI YES NON NO DEP...

Страница 10: ...butE Vent CAME rMF1 MULTIFUNCTION RELAY 1 buZZ butE Vent CAME PINI Factory parameters INI SAVE IN01 IN30 Set in Factory CYCL No of cycles performed x 1000 Information ERR Last 10 recorded errors Errx EFFA Information MOTR ASYN BRUS motor type selection Set in Factory BAUD CAN parameter Not used PRTE CAN parameter Not used END of CONFIGURATION To exit the parameters menu simultaneously press and If...

Страница 11: ...or blocking in closing ESCL Slave mode Door not opened but the Obstacle relay activated The controller time out reversal must be set to 0 MA 1 Master mode 1 Door completely opened with time out in case blocking or cell detection with the Obstacle relay activated MA 2 Master mode 2 Door opens as long as the cell signal lasts in case of cell detection Otherwise door immediately closed The Obstacle r...

Страница 12: ...st be performed CMD1 RMF2 Choice of multifunction output relays use BUZZ a buzzer sounds when the door moves RMF1 Learning reset nudging movements or fail stop BUTE intermediate end stop control when two open travel ranges are to be used CAME driving of an electro cam for swinging door type BATT or MOBI or for shutter door type FI VENT an electromagnetic suction disc is driven to keep the door loc...

Страница 13: ...Co andCHvery large SHEETMETAL GLAZED SHEETMETAL GLAZED SHEETMETAL SHEETMETAL GLAZED GLAZED To confirm the selected parameters quit parameter setting by simultaneously pressing and when all the parameter settings are made CYCL Informative display Indicates the number of cycles in thousands performed by the card since its commissioning This number cannot be reset to 0 Err Informative display Indicat...

Страница 14: ... exit from the CMD3 command press Make sure that the motor rotates in the right direction If not return to the parameters and change the SMot parameter Make sure that the door operates correctly mechanically from end stop to end stop and that the skate correctly unlocks the landing door OPERATOR TRAVEL LEARNING Start the travel learning with the CMD1 command Scroll the menus by successively pressi...

Страница 15: ... U2 F FP O FP F CS F FS O RA F FS F U1 S U FR FF O U FR FF F U1 S U1 O U1 F CS O CL O CL F Skate travel Panels travel Clea opening Panels travel Clea opening Skate travel FP O FP F U2 O U2 F FS O RA F U FR FF F U1 O U1 F CS O CL O CL F U1 S U FR FF O FF F Panels travel Clea opening Panels travel Clea opening FP O FP F U2 O U2 F RA O RA F U FR FF O U FR U1 O U1 F CL O CL F Panels travel Clea openin...

Страница 16: ...nimise the noise The slow travels allow adjusting the door dockings according to their speed or their inertia The hardnesses are expressed in of speed drop The card records the real cruise speed each time the door is opened or closed and analyses abnormal deviations An exceeding of the adjusted percentage in DURF during closing triggers a re opening and in DURO for opening triggers a finger unjamm...

Страница 17: ...Frequency FM O 5 to 10 Hz Closing Cruise Frequency FP F 2 to 50 Hz End of Closing Frequency FF F 2 to 5 Hz Closing Skate Frequency FS F 3 to 7 Hz Closing controller Frequency FM F 5 to 10 Hz Opening Acceleration Ramp RA O 1 to 3 s Opening Deceleration Ramp RD O 1 to 3 s Opening Acceleration Ramp RA F 1 to 3 s Opening Deceleration Ramp RD F 1 to 3 s Slow Closing Travel CL F 1 to 150 Pts Slow Openin...

Страница 18: ... open voltage Msto Hold under close voltage MstF Opening Cruise frequency FP O End Of Opening frequency FF O Opening Sabre frequency FS O IN xx INIT List N 1 List N 2 Work parameters Saved adjusted list List N 3 List N SAVE TABLES OF STORED FACTORY VALUES USED VALUE TABLE SAVED SITE CLASSIFIED BY DOOR TYPE CAN BE READ AND CHANGED PARAMETERS TABLE To avoid an accidental backup the SAVE instruction ...

Страница 19: ...O 2 to 5 Hz Opening Skate Frequency FS O 3 to 7 Hz Opening Handling Frequency FM O 5 to 10 Hz Closing Cruise Frequency FP F 2 to 50 Hz End of Closing Frequency FF F 2 to 5 Hz Closing Skate Frequency FS F 3 to 7 Hz Closing controller Frequency FM F 5 to 10 Hz Opening Acceleration Ramp RA O 1 to 3 s Opening Deceleration Ramp RD O 1 to 3 s Opening Acceleration Ramp RA F 1 to 3 s Opening Deceleration ...

Страница 20: ... this mode the motor is activated in the open direction and in the close direction The motor is stopped when the button is released This command is among others intended to check the motor s rotating direction or the door s operation To quit this mode press This mode activates only the motor and not the card outputs CMD5 Openings and closings by O and F Close Accessible only if the learning CMD1 h...

Страница 21: ... opening The CMD4 mode is the same as the CMD3 mode but actuates the intermediate end stop and operates in partial travel To quit this mode press This mode activates only the motor and not the card outputs CMD6 Intermediate openings and closings with and The CMD6 mode is the same as the CMD5 mode but the key actuates the intermediate end stop and starts a partial open cycle This mode is only acces...

Страница 22: ...ose order starts the close cycle even if the open order is activated this allows overriding the open order and operating only with a close order The engaged cycle is terminated even if the close order is de activated case of controllers operations which de activate the order as soon as they are shunted even though the skate is still not closed While closing if the door encounters an obstacle it tr...

Страница 23: ... action on the door to close it will trigger a motor driven opening action RESET OPERATION After a power failure the door needs to reset its zero point To do this the door normally waits for the orders and execute them in slow speed At the first opening it saves zero point At the following closing it checks that the traversed travel corresponds to that of the learning Then the door executes the or...

Страница 24: ...c suction disc to keep the door closed This function controls the de activation when the open order appears by applying a short timeout at the departure of the door panels to allow a complete demagnetisation C Buzzer It is activated during a reset after a power failure during a nudging slow forced closing and during forced CMD keyboard commands D Electro cam The electro cam command is managed acco...

Страница 25: ...it is necessary to increase the skate open travel CS O by the value of the VPC unlocking travel so that it is opened in slow speed before the acceleration of the door panels to avoid making noise ENERGY SAVE OPERATION Motor consumption energy save For the sake of saving energy and reducing equipment wear it is possible to allow the ARIANE card to go into reduced opening and closing speeds if calls...

Страница 26: ...Ref 26702 26 07 01 15 Pressing any key switches the display on ...

Страница 27: ...t display mode Press displays the encoder position 0000 Press again displays the segments _ _ To set the display mode press Details about the meaning of the segments leds lit Inputs Outputs active Door open Door close command command input input Inspection Encoder channels A and B input Intermediate open command input Multifunction Opening limit Cell relay outputs Switch output input Shock output ...

Страница 28: ...vely to go to Err validate The screen displays the last stored fault Example of display 0 8 Most recently stored fault 0 Error 8 Press display 1 xx previous fault Continue to press display 9 xx oldest stored fault When is pressed the fault stock contents are displayed in the reverse order How to clear the stored fault stack Scroll the menus by successively pressing Select PARA by pressing Press su...

Страница 29: ...s U1 etc Err4 Motor overcurrent detected Stops the motor for 0 5 seconds If the fault occurs more than five times in less than a minute the message remains displayed and the motor can no longer be commanded for 1 minute Check the motor wirings short circuit voltages U1 Err5 Overload detected Reduces the value of the voltage applied to the motor to limit the overload Check the motor reduce the volt...

Страница 30: ...ed ENCODER POSITION DISPLAY To make sure that the counting operates correctly particularly if an Err6 fault present the counting value may be viewed during the operation in the Position display mode The repeatability of the value 0 in opening operations and that of the value of the maximum travel value in closing operations may be checked To do this simply select the Position display mode To go in...

Страница 31: ...us motor in parameters Reload parameters tables INxx Corresponding to the door type controlled see Notice configuration following door type CAUSES Memory Fault Connector disconnected in the unit Ventilation fault or parametering fault Motor fault Parametering fault Motor fault Parametering fault Faulty encoder Faulty motor Faulty motor wiring Mains power voltage superior to 270V For heavy doors eq...

Страница 32: ...contact Check with display card inputs outputs state See notice CAUSES Retiming opening order drops before the opening end of cycle The door does not find its learning cycle and remains in retiming case for learning done without the landing door or landing doors unlocking bad vertical alignment Operation fail soft case where the door does not see the encoder anymore Strong power voltage drop durin...

Страница 33: ...peration Parameter CELL on NO ensivity bad setting Closing order wired at the bad place on NUDGING Skate closing problem end of closing travel not connected to the control Cell parameter on YES while cell is not connected to ARIANE unit Door random operation reopening on shock several times before closing from time to time the door is operating abnormally The door opens normally and close slowly S...

Страница 34: ...Ref 26702 34 07 01 15 ...