Electrical Installation
AC Motor driven Pump Unit Pre-Startup
•
Leave Stabilizer system off at control panel. (Bypass and dump valves will be open)
•
Check oil level in tank and open cock valves (if present) on AC pump feed line.
•
Open the Manual Unloading Valve by turning the wheel fully anti-clockwise.
•
AC motor pre-startup from PHC-3: See MANUAL OPERATION – See ABB MANUAL for fi rst start details - START VFD procedure in PHC-3 manual.
•
Monitor oil level and stop the AC pump and refi ll oil if required.
•
When pres-startup is completed, close the Manual Unloading Valve.
•
Check for oil leaks and tighten if required.
MC_0218
IMPORTANT
The yachts main engine(s) must be switched off during this procedure. The fi rst start of the AC Motor/Pump Unit must be carried out
manually from the PHC-3 control panel. However, before performing pre-startup procedure from the PHC-3 ensure the VFD(variable
frequency drive) is in REMOTE mode. The VFD panel is factory programmed, therefore no additional functional programming should be
required.
Complete the checklist found at the back of this manual before pressurizing the system!
IMPORTANT
Verify the drive direction in accordance with the direction arrow label on the AC Motor/Pump Unit. To better see/feel the drive