15
5267
15
2022
-
PHC-3
DIAGNOSTIC - Bow Thruster
DIAGNOSTIC - Stern Thruster
Shows live update of inputs and outputs related to bow thruster function.
In Display
Description
Joystick: 25%
The amount of thrust from the joystick/control device. Negative value indicates thrust to port side.
Output: 15.8V 63%
Valve signal voltage and spool travel (valve opening) in percent. Negative value indicates thrust to the
opposite direction.
Crossover: 1
Indicates if the crossover valve is activated. 0=deactivated, 1=activated, - =no crossover output defi ned
Sys.Pressure: 49 bar
System pressure
Spool Travel: 100%
Shows what the MAX SPOOL TRAVEL parameter 2003 is set to. Output are limited to this value.
Bow spool travel optimization:
1. Set MAX SPOOL TRAVEL parameter 2003 to 100%.
2. Enter this menu DIAGNOSTIC – BOW THRUSTER.
3. With a joystick panel (PJC) increase the bow thrust slowly to you reach maximum thrust and
maximum Sys.Pressure.
4. Set MAX SPOOL TRAVEL parameter 2003 to what Output in % shows at maximum thrust and
maximum Sys.Pressure.
Shows live update of inputs and outputs related to stern thruster function.
In Display
Description
Joystick: -27%
The amount of thrust from the joystick/control device. Negative value indicates thrust to port side.
Output: 8.1V -65%
Valve signal voltage and spool travel (valve opening) in percent. Negative value indicates thrust to port
side.
Crossover: 1
Indicates if the crossover valve is activated. 0=valve open, 1=valve closed, - =no crossover output defi ned
Sys.Pressure: 49 bar
System pressure
Spool Travel: 100%
Shows what the MAX SPOOL TRAVEL parameter 2103 is set to. Output is limited to this value.
Stern spool travel optimization:
1. Set MAX SPOOL TRAVEL parameter 2103 to 100%.
2. Enter this menu DIAGNOSTIC – STERN THRUSTER.
3. With a joystick panel (PJC) increase the stern thrust slowly to you reach maximum thrust and
maximum Sys.Pressure.
4. Set MAX SPOOL TRAVEL parameter 2103 to what Output in % shows at maximum thrust and
maximum Sys.Pressure.
Menu - Diagnostic
MC_0201
Menu - Diagnostic
5.1
5.
5.2
Menu - Diagnostic
MC_0201
DIAGNOSTIC - Stabilizer
DIAGNOSTIC - Digital Outputs
Shows live update of inputs and outputs related stabilizer function.
In Display
Description
Sys.Pressure: 113 bar
System Pressure (PTO/PVG pressure)
Stab.Pressure: 90 bar
Stabilizer Pressure
Power Request YES
Stabilizer Request Power
Source: PTO
Stabilizer Power Source. NONE, PTO or VFD (AC)
Stab:1 Unload:0 Dump:1
Stabilizer Vales Status. 0=0V, 1=valve has power (24V) Stab=Stabilizer, Unload=AC Pump Unload,
Dump=Accumulator Dump
Shows live update of a valve output or digital output.
0 = output is 0 Volt
1 = output is energized
When an output is highlighted, the output will be toggled as long as the
Enter button is being pushed
and held.
In Display
Description
LS-Dump
LS-Dump Valve
Pump #2 Shutdown
Pump #2 Shutdown Valve
Stabilizer
Stabilizer Valve
AC Pump Unload
AC Pump Unload valve
Accumulator Dump
Accumulator Dump Valve
Cooling Hydraulic
Hydraulic Cooling Pump
D-OUTPUT 1
Digital Output 1, See Parameter 0501 for output function
D-OUTPUT 2
Digital Output 2, See Parameter 0502 for output function
D-OUTPUT 3
Digital Output 3, See Parameter 0503 for output function
D-OUTPUT 4
Digital Output 4, See Parameter 0504 for output function
D-OUTPUT 5
Digital Output 5, See Parameter 0505 for output function
D-OUTPUT 6
Digital Output 6, See Parameter 0506 for output function
5.3
5.4
Содержание PHC-3
Страница 30: ...30 5267 15 2022 PHC 3 MC_0037 Notes...