PHC-3
PARAMETERS - 20 Bow Thruster
PARAMETERS - 10 Stabilizer (Cont......)
1021
VFD MAX SPEED
Sets VFD Maximum Speed
MIN SPEED – MAX LIMIT
(default 1500rpm)
The value is limited to VFD settings and parameter 1020 VFD MIN SPEED.
In steps of 10rpm.
1022
VFD TYPE
Selects VFD type
ABB ACS550
ABB ACS550 Drive with Modbus connection
VACON
VACON NX Drive with MODBUS/N2 option board with Modbus connection
ABB ACS580 (default)
ABB ACS580 Drive with Modbus connection
1023
VFD BAUD
Defi nes VFD Modbus communication speed. VFD must be set to same communication speed. Changing
value requires power off/on of PHC-3 to take action. Changing communication settings on VFD will also
require power off/on of VFD.
BAUD19200,8,EVEN,1
19.2 Kbit, 8bit data, parity EVEN, 1 stop bit
BAUD38400,8,EVEN,1
34.8 Kbit, 8bit data, parity EVEN, 1 stop bit
BAUD57600,8,EVEN,1
(default)
57.6 Kbit, 8bit data, parity EVEN, 1 stop bit
BAUD115200,8,EVEN,1
115.2Kbit, 8bit data, parity EVEN, 1 stop bit
No.
Name/Value
Description
2001
VALVE TYPE
Defi nes the bow proportional thruster valve
DEACTIVATED
Deactivates the bow thruster function
DANFOSS PVG (default)
Defi nes Danfoss PVG valve
2002
DIRECTION
Defi nes thruster direction. If the thruster operates to the wrong direction just change the setting here
instead swapping hydraulic hoses on the installation.
This parameter will affect the BOW valve output direction for all parameter 0102-THRUSTER CONFIG
settings.
NORMAL (default)
Normal thruster direction
SWAPPED
Swapped thruster direction
2003
MAX SPOOL TRAVEL
Scaling of valves spool travel (valve opening) for optimized oil flow and dynamics.
For bow spool travel optimization see 1.5.1. DIAGNOSTIC – BOW THRUSTER.
50% - 100% (default
100%)
In steps of 1%
2004
RAMP INCREASE
Defi nes the time the output signal uses to go from 0% to 100%
100ms – 10000ms (default
200ms)
In steps of 100ms
2005
RAMP DECREASE
Defi nes the time the output signal uses to go from 100% to 0%
100ms – 10000ms (default
200ms)
In steps of 100ms
2006
DIRECTION LOCK
Defi nes the time from thruster has stopped to the output can change direction of thrust
500ms – 10000ms (default
1000ms)
In steps of 100ms
2007
CROSSOVER
All 412mm (16inch), 513mm (20inch) and 610mm (24inch) tunnel thrusters, are supplied with hydraulic
bypass/crossover valve and must therefore enable crossover. Disable crossover for all other thrusters. This
crossover valve is normally open to protect the thruster during deceleration and will close while thruster is
running.
When changing to enable crossover the RAMP DECREASE parameter is set to 3000ms, and if changing to
disable the RAMP DECREASE parameter are set to default value. Crossover can also be enabled to other
D-OUTPUT’s, see PARAMETERS - 05-DIGITAL OUTPUTS.
DISABLE
Disables crossover
DO-1 BOW CROSSOVER
Enables crossover to D-OUTPUT 1, NO Valve
DO-1 -BOW CROSSOVER
Enables crossover to D-OUTPUT 1 Inverted output, NC Valve
Menu - Parameters
MC_0201
4.6
4.7
Menu - Parameters
MC_0201
PARAMETERS - 21 Stern Thruster
No.
Name/Value
Description
2101
VALVE TYPE
Defi nes the stern proportional thruster valve
DEACTIVATED
Deactivates the stern thruster function
DANFOSS PVG (default)
Defi nes Danfoss PVG valve
2102
DIRECTION
Defi nes thruster direction. If the thruster operates to the wrong direction just change the setting here
instead swapping hydraulic hoses on the installation.
This parameter will affect the STERN valve output direction for all parameter 0102-THRUSTER CONFIG
settings.
NORMAL (default)
Normal thruster direction
SWAPPED
Swapped thruster direction
2103
MAX SPOOL TRAVEL
Scaling of valves spool travel (valve opening) for optimized oil flow and dynamics.
For stern spool travel optimization see 1.5.2. DIAGNOSTIC – STERN THRUSTER.
50% - 100% (default
100%)
In steps of 1%
2104
RAMP INCREASE
Defi nes the time the output signal uses to go from 0% to 100%
100ms – 10000ms (default
200ms)
In steps of 100ms
2105
RAMP DECREASE
Defi nes the time the output signal uses to go from 100% to 0%
100ms – 10000ms (default
200ms)
In steps of 100ms
2106
DIRECTION LOCK
Defi nes the time from thruster has stopped to the output can change direction of thrust
500ms – 10000ms (default
1000ms)
In steps of 100ms
2107
CROSSOVER
All 412mm (16inch), 513mm (20inch) and 610mm (24inch) tunnel thrusters, are supplied with hydraulic
bypass/crossover valve and must therefore enable crossover. Disable crossover for all other thrusters.
This crossover valve is normally open to protect the thruster during deceleration and will close while
thruster is running.
When changing to enable crossover the RAMP DECREASE parameter is set to 3000ms, and if changing to
disable the RAMP DECREASE parameter are set to default value.
Crossover can also be enabled to other D-OUTPUT’s, see PARAMETERS - 05-DIGITAL OUTPUTS.
DISABLE
This crossover valve is normally open to protect the thruster during
DO-2 STERN CROSSOVER
Enables crossover to D-OUTPUT 2, NO Valve
DO-2 -STERN CROSSOVER
Enables crossover to D-OUTPUT 2 Inverted output, NC Valve
4.8