IDP 800 Terminal Series - Hardware Guide
T209, Version 01 30 © SkyWave Proprietary
3.10 Non-Volatile Storage
The terminal has non-volatile flash memory that is shared by the terminal firmware and
user services.
Parameter
Value
Non-volatile On-board Flash Storage
8 MB
16
Write-Erase Cycles (per operating life)
100 000
3.11 Environmental
Parameter
Description
Humidity
The terminal meets all its specifications after exposure to 90%
relative humidity at +85°C, per the test methodology of SAE
J1455, section 4.2.3.
Vibration
The terminal meets all its specifications during exposure to
random vehicular vibration levels per SAE J1455, section
4.10.4.2 and MIL-STD-810G, section 514.6, fig 514.6C-1.
Mechanical Shock
The terminal meets all its specifications after exposure to positive
and negative saw tooth shock pulses with peaks of 20G and
durations of 11 ms as specified in MIL-STD-810G, section 516.6,
Procedure I, section 2.3.2c, 3/axis/(positive and negative
direction).
Altitude
The terminal meets all of its specifications after a non-operating
12.2 km altitude test as detailed in SAE J1455, section 4.9.3,
except with an ambient temperature of -5°C.
Thermal Shock
The terminal meets all of its specifications after a thermal shock
test as detailed in SAE J1455, section 4.1.3.2.
Salt Spray
Atmosphere
The IDP-800 meets all of its specifications after a salt spray test
as detailed in SAE J1455, section 4.3.3.1.
Immersion
The terminal meets all of its specifications after a 6 hour
alternating hot/cold salt water immersion test as detailed in SAE
J1455, section 4.3.3.2.
The terminal meets all of its specifications after a 30 minute, 1 m
depth fresh water immersion test as detailed in IEC 60529,
section 14.2.7.
These immersions were performed without a cable mating with
the circular connector.
Exposure to
Chemicals and Oils
The terminal meets all of its specifications after a light to
moderate splash test as detailed in SAE J1455 section 4.4.3.2, for
the following chemicals:
Window Washer Solvent
16
The IDP-800 has 8MB compared to 4MB on IDP-600 series terminal. It is strongly
recommended that applications restrict usage to 4MB memory as the additional 4MB should be
reserved for future Lua framework features.