IDP 600 Terminal Series - Hardware Guide
© SkyWave Proprietary 11 T200, Version 02
3.2.2
Power Consumption
Typical power consumption values at Vbatt=12 V and at room temperature (22°C)
Table 4
Power Consumption Values
Mode of Operation
Current
Transmit
0.75 A
Receive
45 mA
Sleep
100 µA
Processing
10 mA
3.2.2.1
Average Power Consumption
Average terminal power consumption depends on many factors including how often the
modem wakes to receive to-mobile messages, how often GPS fixes are requested, and
how often from-mobile messages are sent. Table 5 characterizes several scenarios and
shows the estimated average power consumption assuming a 12 V power source.
Table 5
Power Consumption Scenarios
Scenario
Fixed 1
Fixed 2
Mobile 1
Mobile 2
Mobile 3
Wake to Receive
Period
30 min
3 min
60 min
30 min
10 min
Tx/Day and
Message Size/Tx
48X,
98 bytes
96X,
98 bytes
1X,
98 bytes
2X,
98 bytes
2X, 98
bytes
GPS Fix/Day
1
(network)
1
(network)
24
4
(network)
4
(network)
Power Mode
Fixed -
battery
Fixed -
battery
Mobile -
powered
Mobile -
battery
Mobile -
battery
Average Power
Consumption
(mAh/day at 12 V)
24
111
16
11
25
Serial (terminal
only)
On Rx
Wake Up
On Rx
Wake Up
On Rx Wake
Up
None
None
Notes
-
-
10 seconds of
application card
geofence
processing per
fix (assumed)
(terminal only)
-
-
3.2.3
Load Dump Circuitry
The terminal's operating range is 9-32 V. Above this range; the load dump protection
circuitry opens an electronic switch so that the terminal is not damaged, up to 150V.
When the voltage drops below the threshold, the terminal recovers, going through power
on reset.
With this protection, the terminal is capable of withstanding load dumps as specified in
SAE J1455 (rev JUN2006) paragraph 4.13.2.2.1.