Skytech: 5320P
REV. 8-11-20 Page 7
• Before installation, make sure you turn the slide switch to
OFF
. After installation, make sure you turn the slide switch
to
REMOTE
.
• The remote receiver can be placed on the fireplace hearth or under the fireplace behind the control access panel.
• Use the wires attached to the remote receiver to connect to the gas valve or the electric module (piggyback
connectors have both male & female terminals for flexibility).
• Be sure that the connectors do not touch each other or other bare metal surfaces; this will cause the appliance to turn
ON. The connectors may be wrapped with electrical tape to prevent this.
INSTALLATION
Protection from extreme heat is very important. The remote receiver should be kept away from temperatures exceeding
130ºF. Extreme heat can cause damage, which is not covered under warranty.
WIRING INSTRUCTIONS
A qualified electrician should install the remote control system.
REMOTE RECEIVER
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP
TP
TH
THERMOPILE/
PILOT LIGHT
MILLIVOLT VALVES
MILLIVOLT SYSTEM CHECK
• Ensure that the pilot flame is lit.
• Slide the 3-position button on the remote receiver to the
ON
position. The main gas flame (i.e., the fire) should ignite.
• Slide the button to
OFF
. The main flame should extinguish
(the pilot flame will remain on).
• Slide the button to
REMOTE
, then press the
ON
button on
the transmitter to change the system to ON. The main gas
flame should ignite.
• Connect one wire from the remote receiver to the TH terminal
on the gas valve.
• Connect the other wire from the remote receiver to the TH/TP
terminal on the gas valve.
Fig. 22
Millivolt wiring.
ELECTRONIC MODULE
TR
TH
neutral wire
24VAC
hot wire
110/24VAC
Transformer
REMOTE RECEIVER
The remote control receiver can be connected, in series, to a 24VAC
transformer to the TR (transformer) terminal on the ELECTRONIC
MODULE. Connect the hot wire from the 24VAC transformer to
either of the wires on the remote receiver. Connect the other wire from
the receiver to the TH (thermostat) terminal on the
ELECTRONIC MODULE.
ELECTRONIC SPARK IGNITIONS
Fig. 23
Electronic wiring.
ELECTRONIC SPARK SYSTEM CHECK
• Slide the 3-position button on the remote receiver to the
ON
position. The spark electrode should begin sparking to ignite
the pilot. After the pilot flame is lit, the main gas valve should
open and the main gas flame should ignite.
• Slide the button to
OFF
. The main gas flame and pilot flame
should both extinguish.
• Slide the button to
REMOTE
, then press the ON button on
the transmitter to change the system to ON. The spark elec-
trode should begin sparking to ignite the pilot. After the pilot
is lit, the main gas valve should open and the main gas flame
should ignite.