Skytech: 5320P
REV. 8-11-20 Page 5
Weekends (Sat. - Sun.)
Weekdays (Mon. - Fri.)
Program
ON
OFF
TEMP
ON
OFF
TEMP
P1
P2
Table 2
To note custom programming
COMMUNICATION - SAFETY (C/S - TX)
This remote control has a COMMUNICATION –SAFETY function built into its software.
It provides an extra margin of safety when the Transmitter is out of the normal 20-foot
operating range of the receiver.
At all times and in all OPERATING MODES, the transmitter sends an RF signal every
15 minutes, to the receiver, indicating that the transmitter is within the normal operating
range of 20-feet. Should the receiver NOT receive a transmitter signal every 15
minutes, the receiver will begin a 2 hour (120 minute) countdown timing function. If
during this 2-hour period, the receiver does not receive a signal from the transmitter,
the receiver will shut down the appliance being controlled by the receiver. The
receiver will then emit a series of rapid “beeps” for a period of 10 seconds. Then after
10 seconds of rapid beeping, the receiver will continue to emit a single “beep” every
4 seconds until a transmitter MODE button is pressed to reset the receiver.
MODE
MODE
SET
PROG
Fig. 17
Operating modes.
CHILDPROOF “LOCK-OUT” - (CP)
This remote control includes a CHILDPROOF “LOCK-OUT” feature that allows
the user to “LOCK-OUT” operation of the appliance from the TRANSMITTER.
• To activate the “LOCK-OUT” feature, press and hold the
UP
touch button and the
SET
button together for 5 seconds. The lock icon will appear on the LCD screen.
• To disengage the “LOCK-OUT”, press and hold the
UP
touch button and the
SET
button together for 5 seconds or more, the lock icon will disappear from the LCD
screen and the transmitter will return to its normal operating condition.
• When the Transmitter is in “LOCK-OUT” mode, programmed functions will go on with-
out interruption; Only manual functions are prevented.
Fig. 18
Childproof lock-out.
NOTE:
If you are in Manual Mode, then change to Program Mode during the Program Off segments, the transmitter will switch to
Manual OFF.
If you are in the Thermostat Mode, then change to Program Mode during the Program OFF segments, the transmitter will
switch back to Thermostat mode.
To turn the Program Mode OFF, press the PROG button. The word PROGRAM will disappear from the LCD screen
remote.