242
Operating Instructions ACU
09/08
Example:
The following warning status is displayed:
A008D Ixt IxtLt Tc PTC
The warning status results from the hexadecimal sum of the warning
codes (0001+0004+0008+0080 = 008D).
The short-term overload (1 s), warning limit heat sink temperature and
warning limit motor temperature warnings are present.
Output signals
The output of a warning message is signaled.
169 - General Warning
1)
The output of a warning message in
Warnings
269 is
signaled.
11 - Warning, General
2)
1)
For linking with inverter functions
2)
For digital output
Meaning of code displayed by parameter
Application Warning Status
367
:
Code
Warning Status
A 00 00 NO WARNING
No warning message present.
A
00 01 BELT
Warning V-belt by
Operation mode
581
.
A
00 02 SW-LIM CW
The positive SW limit switch was reached (parameter
Positive SW limit switch
1145
).
A
00 04 SW-LIM CCW
The negative SW limit switch was reached (parameter
Negative SW limit switch
1146
).
A 00 08 HW-LIM CW
The positive HW limit switch was reached.
A 00 10 HW-LIM CCW
The negative HW limit switch was reached.
A
00 20 CONT
The contouring error monitoring range adjusted with
parameter
Warning Threshold
1105
was left.
Output signals
The output of an application warning message is signaled.
216
- Application Warning
1)
The output of a warning message in
Application
Warnings
273 is signaled.
26 - Warning, Application
2)
1)
For linking with inverter functions
2)
For digital output
Operating Instructions ACU
09/08
242
Содержание Bonfiglioli Vectron ACTIVE CUBE ACU 201 Series
Страница 1: ...ACTIVE CUBE Operating Instructions Frequency Inverter 230V 400V 0 25 kW 132 kW ...
Страница 2: ......
Страница 259: ......