09/08
Operating Instructions ACU
99
Configuration 430, sensorless field-oriented control
with speed/torque control
Configuration 430 extends the functionality of Configuration 410 by functions for
torque-dependent, field-oriented control. The reference torque is represented as a
percentage and it is transmitted into the corresponding operational performance of
the application. Change-over between variable-speed control and torque-dependent
control is done jerk-free during operation.
Configuration 210, field-oriented control
Configuration 210 contains the functions for speed-controlled, field-oriented control
of a 3-phase machine with speed sensor feedback. The separate control of torque
and flux-forming current enables high drive dynamics with a high load moment. The
necessary speed sensor feedback results in a precise speed and torque performance.
Configuration 211, field-oriented control with technology controller
Configuration 211 extends the functionality of Configuration 210 by a Technology
Controller, which enables a control based on parameters such as flow rate, pressure,
contents level or speed.
Configuration 230, field-oriented control
with speed/torque control
Configuration 230 extends the functionality of Configuration 210 by functions for
torque-dependent, field-oriented control. The reference torque is represented as a
percentage and it is transmitted into the corresponding operational performance of
the application. Change-over between variable-speed control and torque-dependent
control is done jerk-free during operation.
Configuration 510, field-oriented control of synchronous machine, speed
controlled
Configuration 510 contains the functions for speed-controlled, field-oriented control
of a synchronous machine with speed sensor feedback. The separate control of tor-
que and flux-forming current enables high drive dynamics with a high load moment.
The necessary speed sensor feedback results in a precise speed and torque perfor-
mance.
Configuration 530, field-oriented control of synchronous machine
with speed/torque control
Configuration 530 extends the functionality of Configuration 510 by functions for
torque-dependent, field-oriented control. The reference torque is represented as a
percentage and it is transmitted into the corresponding operational performance of
the application. Change-over between variable-speed control and torque-dependent
control is done jerk-free during operation.