09/08
Operating Instructions ACU
227
18
Actual Values
The various control functions and methods include electrical control variables and
various calculated actual values of the machine or system. The different actual values
can be read out for operational and error diagnosis via a communication interface or
in the VAL menu branch of the operating unit.
18.1
Actual Values of the Frequency Inverter
The modular hardware of the frequency inverter enables application-specific adapta-
tion. Further actual value parameters can be displayed as a function of the selection
configuration and the installed expansion cards.
Actual Values of the Frequency Inverter
No.
Description
Function
222 DC –Link Voltage
Direct voltage in the DC link.
223
Modulation
Output voltage of the frequency inverter relative to
the mains voltage (100% = U
FUN
).
228 Internal ref. frequency
Sum of the
Frequency reference value sources
475 as
a reference value from the frequency reference value
channel.
229
Reference percentage
Sum of the
Reference percentage sources
476 as a
reference value from the reference percentage chan-
nel.
230
Actual percentage val-
ue
Actual value signal on the
Actual percentage source
478
.
243
Digital Inputs (Hard-
ware)
Decimally coded status of the six digital inputs and of
multifunctional input 1 in
Operation Mode
452
- digi-
tal input. Displays the status of the physical inputs
(See also
Digital Inputs
250
).
244 Working hours counter Operating hours in which the output stage of the in-
verter is active.
245
Operation hours coun-
ter
Operating hours of the frequency inverter in which
supply voltage is available.
249 Active data set
The data set actively in use according to
Data set
change-over 1
70 and
Data set change-over 2
71.
250
Digital Inputs
Decimally coded status of the six digital inputs and of multi-
functional input 1 in
Operation Mode
452 - digital input.
Depending of the setting of parameter
Local/Remote
412
the hardware signals or Fieldbus/Systembus signals are
displayed (See also
Digital Inputs(Hardware)
243)
251
Analog input MFI1A
Input signal on multifunctional input 1 in
Operation
mode
452 - analog input.
252
Repetition Frequency
Input
Signal on repetition frequency input according to
Op-
eration mode
496.
254
Digital Outputs
Decimally coded status of the two digital outputs and
of multifunctional output 1 in
Operation mode
550 –
digital.
255 Heat sink temperature Measured heat sink temperature.
256 Inside temperature
Measured inside temperature.
257 Analog output MFO1A
Output signal on multifunctional input 1 in
Operation
mode
550 – analog.
258
PWM-Input
Pulse-width modulated signal at PWM input according
to
Operation mode
496.
259 Current error
Error message with error code and abbreviation.
Operating Instructions ACU
227
09/08