2020.06.26
• 612321
5.2 Regulation Set Without Universal AIC
The regulation set is located in a bag behind the
flap.
522007 DA 1200 Clamp for pull rod
522940 Nylon cord
522048 String and pull rod holder
352795 Chipboard screw
The picture illustrates various kinds of mounting
and pull to the right and left side respectively.
Place the clamp as shown; clamp must be placed
identically along the entire length of the pull rod.
Mount the string and the pull rod holder using the
included stainless screws.
Only when all line guides have been mounted, the
pull rod is pushed into place.
Always place the clamp identically in relation to
the string and pull rod holder so there will be as
little readjustment as possible. The distance must
be approx 100mm when the ventilation system is
closed.
522007
522940
522048
352795
Содержание DA 1200 Wall Inlet
Страница 5: ...2020 06 26 612321 PRODUCT SURVEY 1 General Drawing of DA 1200 Wall Inlet...
Страница 27: ...2020 06 26 612321 6 6 Door set for Wire Rope Drive Min 40 cm Min 40 cm...
Страница 30: ...7 3 DA 1200 Inlet Cover 7 4 DA 1200 Light Trap for Inlet Cover...
Страница 31: ...2020 06 26 612321 7 5 DA 1200 fly screen for inlet cover...