E
n
g
l
i
s
h
SKF TMEA 2
Shaft alignment tool
27
3.8.3
Horizontal alignment
Move the measuring units to the
3 o'clock position (fig. 23).
Observe the coupling and feet
values live adjustment.
Machine misalignment should be
within the manufacturer's
specified tolerances. In case such
tolerances are missing, table 1
can again be used as a general
recommendation.
a) If the measured coupling
values are within the
tolerances, no sideways
adjustment is necessary.
b) If the measured coupling
values are higher than the
acceptable tolerances check
the recommended correction
on the feet.
Fig. 23. The 3 o'clock position
Fig. 24. Horizontal alignment