24
Shaft alignment tool
SKF TMEA 2
3.8
Alignment results
3.8.1
Measured
misalignment
After the second measurement at
3 o'clock has been confirmed, the
misalignment of the two machines
in the measurement plane, the
plane where the measuring units
are (i.e. horizontal in this case) is
displayed (fig. 19).
Coupling values
The coupling value on top of the
display shows the angle between
the centre lines of the two shafts
in the measurement plane
(measured in mm/100 mm or
0.001"/1").
The value below on the display
shows the parallel off-set of the
two centre lines in the
measurement plane.
These two values are the coupling
values in the measurement plane.
Feet values
The values F1 and F2 on the display indicate the relative positions of
the Movable machine in the measurement plane.
The F1 value indicates the relative position of the front pair of feet of
the Movable machine.
The F2 value indicates the relative position of the rear pair of feet of
the Movable machine.
Fig. 19. Measured misalignment