10. Faults
Page 27
EN
Working on products which have not
been disconnected from the power
supply can cause injury to persons.
Assembly, maintenance, and repair
work may only be carried out by
qualified experts on a product that is not
connected to a power supply. The
supply voltage must be turned off
before any product components are
opened.
The hot surfaces of a motor can cause
burns. The surfaces of motors should
only be touched by persons wearing
appropriate protective gloves or once
the motor has been stopped for a long
period time.
Conveying systems are under pressure
when they are being operated. They
must therefore be depressurized before
assembly, maintenance or repair works
begin and before any changes to the
system are made.
Table 3 continued ? Fault analysis and rectification
Problem
Possible cause
Rectification
Noise, vibrations, or leaks
Shaft seal defective
Replace the shaft seal.
Axial clearance of pump misaligned
Adjust the axial clearance.
Pump not mounted securely
Secure the connecting flange.
Pump shaft hard to turn
Pump blocked
Check the suction opening and clean if required.
Running wheel chafing
Make sure that the running wheel is properly secured and that the pump shaft is not bent or off*centre.
Shaft bearing defective
Replace the shaft bearing.