![SKF LAGD 1000 series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/skf/lagd-1000-series/lagd-1000-series_instructions-for-use-manual_1287164032.webp)
32
SKF LAGD 1000
8. Technical data
LAGD 1000/DC
LAGD 1000/AC
Max. operating
pressure
150 bars (2 175 psi)
150 bars (2 175 psi)
Permissible operating
temperature
-25°C/+75°C
(-13°F/+167°F)
-25°C/+60°C
(-13°F/+140°F)
Number of outlets
10 to 20
10 to 20
Max length of pipes
6 metres (20ft)
6 metres (20ft)
Output of pump
element
2 cm
3
/min
(0.122 in
3
/min)
2 cm
3
/min
(0.122 in
3
/min)
Reservoir capacity
1 l (61 in
3
)
1 l (61 in
3
)
Greases
up to NLGI grade 2
up to NLGI grade 2
Weight
(max depending
on outlets)
3,7 kg (8.2 lbs)
4,8 kg (10.6 lbs)
System of protection
IP65
IP65
Electrical
speciications
Rated voltage
24 V DC
115 V / 50 Hz; 115 V / 60 Hz
230 V / 50 Hz; 230 V / 60 Hz
Typ. power input
at 20°C (68°F) and
max. Operating
pressure
0,5 A
115V
: 1 A / 50 Hz;
1.3 A /60 Hz
230V
: 0.45 A / 50 Hz;
0.66 A / 60 Hz
Содержание LAGD 1000 series
Страница 1: ...SKF LAGD 1000 Instructions for use ...
Страница 10: ...10 SKF LAGD 1000 1 4 LAGD 1000 unit dimensions Fig 2 LAGD 1000 DC dimensions Fig 3 LAGD 1000 AC dimensions ...
Страница 33: ...33 SKF LAGD 1000 ...
Страница 34: ...34 SKF LAGD 1000 ...
Страница 35: ......
Страница 37: ...1 5 0 1 0 0 9 Appendix 1 LAGD 1000 series Mounting hole drilling template MP5234 Appendix ...