SKF LAGD 1000
Example:
Part 1 of total
value.
Note down!
Part 2 of total value
Total value:
00533,8 h
Maximum value:
99999,9 h
12
Indicates fault hours
13/14
Example:
Part 1 of total
value.
Note down!
Part 2 of total value
Total value:
00033,8 h
Maximum value:
99999,9 h
15
LED indicators extinguish
Oh and Fh values are stored in an undeletable way in the
EEPROM
4.3 Programming the LAGD 1000/AC.. and LAGD 1000/DC
Read the complete section before programming!
Before programming the LAGD 1000/AC.. or LAGD 1000/DC.., make a note of what you
want to achieve. This makes the process easier to perform.
4.3.1 Changing the lubrication interval times
The following table gives the running time for one internal cycle of the LAGD 1000/AC..
and LAGD 1000/DC.. One internal cycle equates to 0,2 cm
3
per outlet.
Designation
Number of
outlets
Running time (tCo) for one
internal cycle of progressive
feeder giving 0,2 cm
3
/outlet
(minutes)
LAGD 1000/AC10
10
1,0
LAGD 1000/AC12
12
1,2
LAGD 1000/AC14
14
1,4
LAGD 1000/AC16
16
1,6
LAGD 1000/AC18
18
1,8
LAGD 1000/AC20
20
2,0
Содержание LAGD 1000 series
Страница 1: ...SKF LAGD 1000 Instructions for use ...
Страница 10: ...10 SKF LAGD 1000 1 4 LAGD 1000 unit dimensions Fig 2 LAGD 1000 DC dimensions Fig 3 LAGD 1000 AC dimensions ...
Страница 33: ...33 SKF LAGD 1000 ...
Страница 34: ...34 SKF LAGD 1000 ...
Страница 35: ......
Страница 37: ...1 5 0 1 0 0 9 Appendix 1 LAGD 1000 series Mounting hole drilling template MP5234 Appendix ...