5. Faults
Check level in reservoir at regular intervals. If the reservoir has been emptied
completely, the entire system must be bled after topping up.
All fault messages are displayed as a centralized alarm via the LED
or
FAULT,
depending on version. When a fault message is given, the control unit stops
the normal sequence of operations. The fault concerned is stored and displayed. The
cause of the fault can be read on the display. This considerably helps the fault diagnosis.
5.1 Displaying faults
5.1.1 LAGD 1000/AC.. and LAGD 1000/DC.. faults
Start display mode by pressing one of the two keys
. Operate until fault is
displayed.
Display
Meaning
F
ault
L
ow
L
evel:
Lubricant has dropped below minimum level in reservoir
The further sequence of operations is stopped
F
ault
C
ycle
S
witch:
No signal from cycle switch during pump running time
Blo
ck operation:
Signal from cycle switch missing. Contrary to normal operation, the control
unit is still in the monitoring mode. If the fault continues to exist for three
pump running periods, a fault message is displayed
Содержание LAGD 1000 series
Страница 1: ...SKF LAGD 1000 Instructions for use ...
Страница 10: ...10 SKF LAGD 1000 1 4 LAGD 1000 unit dimensions Fig 2 LAGD 1000 DC dimensions Fig 3 LAGD 1000 AC dimensions ...
Страница 33: ...33 SKF LAGD 1000 ...
Страница 34: ...34 SKF LAGD 1000 ...
Страница 35: ......
Страница 37: ...1 5 0 1 0 0 9 Appendix 1 LAGD 1000 series Mounting hole drilling template MP5234 Appendix ...