9.2 Start of operation after
malfunction repair
To restart device following repair of the malfunction, perform the
steps described in
Installation 6.3.2.
Malfunction
Possible cause
To repair malfuction
To be repaired by
Significant increase in
noise during
operation
Incorrect load
Ensure that the load of the pillar does not exceed
the load limit in the technical specification
Qualified personnel
Obstacle in the stroke area
of the device
Remove all obstacles in the stroke area
Operator
Motor, gearbox or nut
defective
The pillar must not continue to be operated.
Contact SKF service.
Qualified personnel
Play in the guiding
system
Sliding elements are worn
Replace drive unit
Qualified personnel
Drive unit vibrations
during movement
Incorrect service load
Ensure that the load of the pillar is in the optimal
range (no over- or underload) as defined in the
technical specification
Qualified personnel
Wear or failure in the
mechanical brake
Contact SKF service
Qualified personnel