10. Maintenance
- 67 -
951-181-014-EN
Version 16
Checklist maintenance of ELNOR motors
Activity to be done
Interval / deadline
Check the current and earth cables for damages and proper installation
Interval depends on the operating conditions, at the latest, however, every
4 weeks
First inspection
Every 500 operating hours or every 6 months
Main inspection
Once a year:
○
Check rolling bearing and replace, if necessary
○
Change radial sealing ring
○
Check for outside damages
○
Check for traces of an explosion within the pressure-encapsulated motor
○
Check the function of the thermal circuit breaker