background image

Form 37714 Rev 2002

Page 10 of 13

www.skcinc.com

Accessories/Replacement Parts

Accessories 

Cat. No.

chek-mate Calibrator with CalChek,

 0.50 to 5 L/min, includes 9-volt alkaline battery and 

NIST-traceable certificate

375-0550N

Low Flow Sampling

Low Flow (5 to 500 ml/min) Kit

 includes All-in-One low flow holder and Type A tube cover

210-500

Adjustable Low Flow Tube Holders

Use with CPC listed below. Require separate tube covers listed below

Dual Holder

224-26-02

Tri Holder

224-26-03

Quad Holder

224-26-04

Constant Pressure Controller (CPC)

224-26-CPC

Protective Tube Covers for Sorbent Tubes

Use with adjustable low flow tube holders listed above.

 

Type A -

 6-mm OD x 70-mm L, included in Low Flow Kit above

224-29A

 

Type B -

 8-mm OD x 110-mm L

224-29B

 

Type C -

 10-mm OD x 150-mm L

224-29C

 

Type D -

 10-mm OD x 220-mm L

224-29D

Battery Maintenance

PowerFlex Charging System for SKC Personal Pumps 
 5-Station,

 100-240 V

223-1000

 Single,

 100-240 V

223-2000

 

PowerFlex Pump Cable,

 for AirChek 52

223-1004

Battery Eliminator,*

 connects pump to line power for extended sampling, 115 V

223-300

Pump Operation

Screwdriver Set,

 included with pump

224-11

Protective Nylon Pouch

 with belt and shoulder strap

 Black

224-88

 High-profile 

Red

224-96A

 Noise-reducing 

Black

224-96C

* Not UL Listed for intrinsic safety

Содержание 224-52

Страница 1: ...mpingers cyclones PPIs or filter cassettes Checking Pump Kit Contents Use the table below to verify that you received all items associated with the Cat No ordered If you are missing items contact SKC...

Страница 2: ...nd any warranty Ensure proper orientation of charging cable before plugging it into the charging jack Improper orientation contact will short circuit the battery and voids any warranty Short circuitin...

Страница 3: ...collection medium to the worker in the breathing zone and the pump to the worker s belt using the belt clip When using an impinger an in line trap SKC Cat No 225 22 or 225 22 01 is required between t...

Страница 4: ...ing a small screwdriver turn the flow adjustment screw on top of the pump Figure 1 clockwise to increase flow or counterclockwise to decrease flow until the calibrator indicates 1 5 L min 4 Remove tub...

Страница 5: ...o compensate due to excessive back pressure or a low battery condition exists it will shut down and timing functions will pause The LCD will display either a battery shaped icon or a flow fault icon d...

Страница 6: ...le tubing connect the calibrator outlet suction port to the pump inlet 3 Calculate the sum of all tube flow rates The maximum flow rate through any one tube is 500 ml min a If the sum is 1000 ml min s...

Страница 7: ...to decrease until the calibrator indicates the method specified flow rate Do not adjust the flow rate on the pump Note For tri and quad models first rotate each anti tamper cover to expose the flow ad...

Страница 8: ...elapsed run time Possible Displays During Sampling Flow or Battery Fault Shutdown If the pump is unable to compensate due to excessive back pressure or a low battery condition exists it will shut dow...

Страница 9: ...any warranty and the UL Listing for intrinsic safety 1 Loosen two security screws on bottom of pump case and allow them to fall to the out position 2 Pinch battery pack release arms and pull the botto...

Страница 10: ...4 26 CPC Protective Tube Covers for Sorbent Tubes Use with adjustable low flow tube holders listed above Type A 6 mm OD x 70 mm L included in Low Flow Kit above 224 29A Type B 8 mm OD x 110 mm L 224 2...

Страница 11: ...n illustration N A PC Board P79592 N A Screw and O ring Set complete for one pump P22402 External Case No Description Cat No 1 Battery Pack NiMH P78011AMH 2 Battery Pack Release Arms N A 3 Battery Pac...

Страница 12: ...mpensate for longer than 15 seconds due to excessive back pressure the pump enters flow fault During flow fault the pump stops the fault icon appears on the display and elapsed time remains on the dis...

Страница 13: ...5 48 41 3 0 42 38 Table 1 Pump Run Time in Hours with NiMH Battery Appendix Cont Typical Run Times Table 1 contains the typical run times achieved when using a fully charged NiMH battery pack Data is...

Отзывы: