background image

Form 37714 Rev 2002

Page 11 of 13

www.skcinc.com

Replacement Parts

  Use only SKC-approved parts to ensure reliable performance. Failure to do so voids the UL Listing 

for intrinsic safety and any warranty.

  Use of a repaired or rebuilt battery pack voids any warranty and the UL Listing for intrinsic safety.

  Failure to follow warnings, cautions, and notes voids any warranty.

Internal Stack

No.

Description

Cat. No.

1A/1C

Stack screws, pk/12

P51891

2

Inlet/Hose Connect, includes filter and gasket

P20106

2A

Replacement Inlet Filter, pk/10

P40370

3

Pulsation dampener

P2010802

4

Stack plate

N/A

5A/5B

Valve plates (top and bottom)

P213201

6

Diaphragm/Yoke assembly

P2129B

7

Pump body

P22417G

8

Motor/Eccentric

P518803

9

Pump base plate

P20102

Full Stack without Motor

P20102A

Parts not indicated in illustration:

N/A

PC Board

P79592

N/A

Screw and O-ring Set (complete for one pump)

P22402

External Case

No.

Description

Cat. No.

1

Battery Pack, NiMH

P78011AMH

2

Battery Pack Release Arms

N/A

3

Battery Pack Security Screws

N/A

4

Compensation Pot A

N/A

5

Compensation Pot B

N/A

6

Power Plug for Battery Pack, pk/5

P20107

7

Charging Jack (on rear of battery pack)

N/A

8

Impinger Holder Mounting Screws

N/A

9

Inlet (includes filter and gasket)

P20106

10

Control Cover

P20105

11

Flow Adjustment Screw

N/A

12

Power Switch (on/off)

N/A

13

Belt Clip (not shown)

P20104

14

LCD

P72391

15

External Case

P2010003

SKC Limited Warranty and Return Policy

SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability and the buyer’s exclusive 
remedy. To view the complete SKC Limited Warranty and Return Policy, go to http://www.skcinc.com/warranty.

1A

2A

8

9

2

3

4

7

5A

5B

6

1B

1C

7

AIRCHEK

®

 52

10

3

  9

14

12

  8

  2

  1

2

4    

5    

6    

11

Bottom of pump 

without battery pack

3

15

13

Содержание 224-52

Страница 1: ...mpingers cyclones PPIs or filter cassettes Checking Pump Kit Contents Use the table below to verify that you received all items associated with the Cat No ordered If you are missing items contact SKC...

Страница 2: ...nd any warranty Ensure proper orientation of charging cable before plugging it into the charging jack Improper orientation contact will short circuit the battery and voids any warranty Short circuitin...

Страница 3: ...collection medium to the worker in the breathing zone and the pump to the worker s belt using the belt clip When using an impinger an in line trap SKC Cat No 225 22 or 225 22 01 is required between t...

Страница 4: ...ing a small screwdriver turn the flow adjustment screw on top of the pump Figure 1 clockwise to increase flow or counterclockwise to decrease flow until the calibrator indicates 1 5 L min 4 Remove tub...

Страница 5: ...o compensate due to excessive back pressure or a low battery condition exists it will shut down and timing functions will pause The LCD will display either a battery shaped icon or a flow fault icon d...

Страница 6: ...le tubing connect the calibrator outlet suction port to the pump inlet 3 Calculate the sum of all tube flow rates The maximum flow rate through any one tube is 500 ml min a If the sum is 1000 ml min s...

Страница 7: ...to decrease until the calibrator indicates the method specified flow rate Do not adjust the flow rate on the pump Note For tri and quad models first rotate each anti tamper cover to expose the flow ad...

Страница 8: ...elapsed run time Possible Displays During Sampling Flow or Battery Fault Shutdown If the pump is unable to compensate due to excessive back pressure or a low battery condition exists it will shut dow...

Страница 9: ...any warranty and the UL Listing for intrinsic safety 1 Loosen two security screws on bottom of pump case and allow them to fall to the out position 2 Pinch battery pack release arms and pull the botto...

Страница 10: ...4 26 CPC Protective Tube Covers for Sorbent Tubes Use with adjustable low flow tube holders listed above Type A 6 mm OD x 70 mm L included in Low Flow Kit above 224 29A Type B 8 mm OD x 110 mm L 224 2...

Страница 11: ...n illustration N A PC Board P79592 N A Screw and O ring Set complete for one pump P22402 External Case No Description Cat No 1 Battery Pack NiMH P78011AMH 2 Battery Pack Release Arms N A 3 Battery Pac...

Страница 12: ...mpensate for longer than 15 seconds due to excessive back pressure the pump enters flow fault During flow fault the pump stops the fault icon appears on the display and elapsed time remains on the dis...

Страница 13: ...5 48 41 3 0 42 38 Table 1 Pump Run Time in Hours with NiMH Battery Appendix Cont Typical Run Times Table 1 contains the typical run times achieved when using a fully charged NiMH battery pack Data is...

Отзывы: