background image

Elite Primer Pro High Head Series 

External Pond Pump 

( 6000EPH75, 7500EPH75, 8200EPH82, 9200EPH82, 

11000EPH90, 13000EPH110) 

 

 

 

 

Installation and User’s Guide 

 

 

Summary of Contents for 11000EPH90

Page 1: ...Elite Primer Pro High Head Series External Pond Pump 6000EPH75 7500EPH75 8200EPH82 9200EPH82 11000EPH90 13000EPH110 Installation and User s Guide ...

Page 2: ...age 230v or 115v If they do not match the motor will burn up 3 Choose the correct wire size When in doubt use a heavier gauge larger diameter wire Heavier gauge will allow the motor to run cooler and more efficient 4 Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board 5 Make sure all electrical connections are clean and tight 6 Permanently ground...

Page 3: ...alves are open and strainer pot temperature is cool to touch then with extreme caution CAUTION To prevent damage to the pump and filter and for proper operation of the system clean pump strainer and skimmer baskets regularly WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE WHEN ANY PART OF THE CIRCULATION SYSTEM e g LOCK RING PUMP FILTER VALVES ETC IS SERVICED AIR CAN ENTER THE SYSTEM AND BECOME P...

Page 4: ...ump basket 3 Cover the motor to protect it from severe rain snow and ice 4 Do not wrap the motor in plastic It will cause condensation and rust on the inside of the motor CARE OF ELECTRIC MOTOR PROTECT FROM HEAT Shade the motor from the sun Any enclosure must be well ventilated to prevent overheating Provide ample cross ventilation PROTECT AGAINST DIRT Protect from any foreign matter or splashing ...

Page 5: ...to avoid the possibility of personal injury make sure the suction and discharge valves are open and strainer pot temperature is cool to touch then with extreme caution PUMP DISASSEMBLY CAUTION Be sure not to scratch or mar the polished seal faces Seal will leak if faces are damaged All moving parts are located in rear sub assembly of this pump Tools required 1 2 inch open end wrench 9 16 inch open...

Page 6: ... to clean the seal Press the seal into the impeller with your thumbs and wipe off the ceramic and carbon faces with a clean cloth 3 Remount the seal plate to the motor 4 Screw the impeller onto the motor shaft 5 Remount the diffuser onto the seal plate 6 Grease the diffuser O ring 7 Assemble the motor sub assembly to the strainer pot pump body DO NOT tighten down any of the bolts until all 6 bolts...

Page 7: ...prime and causing the pump to run dry resulting in a damaged seal If the pump is installed below the water level of the water garden close return and suction lines prior to opening hair and lint pot on pump Make sure to re open valves prior to operating The pump strainer pot must be filled with water before the pump is initially started Follow these steps to prime the pump For 2 speed pumps Pump s...

Page 8: ...ve glands on all suction gate valves b Secure lid on pump strainer pot and make sure lid gasket is in place c Check water level to make sure skimmer is not drawing air 2 Pump will not prime not enough water Remedy a Make sure suction lines pump strainer and pump volute are full of water b Make sure valve on suction line is working and open some systems do not have valves c Check water level to mak...

Page 9: ...ved complete the following steps i Remove left hand threaded bolt and gasket ii Remove clean and reinstall impeller iii Reinstall left hand threaded bolt and gasket f Reinstall the diffuser and diffuser O ring g Reinstall motor and seal plate into volute h Tighten bolts securely 3 Pump strainer clogged Remedy a Clean suction trap ...

Reviews: